Malfunction
Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running time
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged housing cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
12
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessive loss in the supply hoses
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean/check supply lines
Clean strainer casings
Reduce hose length to the necessary minimum,
do not use unnecessary connection parts
Clean strainer casings
Reduce hose length to the necessary minimum,
do not use unnecessary connection parts
Clean pump
Note maximum water temperature of +35°C