Error code
Cause
Err 204
Real-time clock temperature
compensation problem.
Installation safety specification
Table 4 RFL100 installation safety specification
Property
Operating environment
For use in wet locations
Operating humidity
Operating altitude
IP rating
IP rating with external power supply
Pollution degree
Frequency band
Batteries
Supply voltage from external power supply
Power consumption
Operating temperature
with alkaline batteries
with lithium batteries
with external power supply
1)
Verify operating temperature specification when using batteries and power supplies not
supplied by Vaisala.
More information
For more information on RFL100 Data Logger, see RFL100 User Guide (M211861EN) available at
www.vaisala.com/rfl100.
1)
Recommended action
If error code Err 200 is also active,
replace the clock battery. If the error
persists, contact Vaisala.
Specification
Indoor use
No
0 ... 100 %RH, non-condensing
Max. 2000 m (6500 ft)
IP54: Limited protection against dust. Protected
from water splashes from any direction.
IP20: Protected against solid foreign objects of
12.5 mm Ø and greater
2
See type label on device
2 × AA sized, 1.5 V (LR6 or FR6)
5 V DC
Max. 1 W
+2 ... +60 °C (+35.6 ... +140 °F)
−20 ... +60 °C (−4 ... +140 °F)
0 ... +60 °C (+32 ... +140 °F)
25