Replacing the paper filter bag/
Illustration
Close the suction connection, see wet
vacuuming.
Replacing the paper filter bag
Illustration
Release and remove the suction head.
back.
Fit new paper filter bag.
Replacing the disposal bag
Illustration
Release and remove the suction head.
Attach the new disposal bag.
tainer.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
22
Troubleshooting
DANGER
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Suction turbine turns off
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replace filled paper filter bag.
Replace the filled disposal bag.
Ensure the filter cover properly locks
into place.
Replace the flat pleated filter.
Test the electrical tool connection.
Dust comes out while vacuuming
Illustration
Check/correct the correct positioning of
the flat fold filter.
Replace the flat pleated filter.
- 7
EN
emptied