Flex VCE 45 M AC Manual Del Usuario página 22

Ocultar thumbs Ver también para VCE 45 M AC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Replacing the paper filter bag/
Illustration
 Close the suction connection, see wet
vacuuming.
Replacing the paper filter bag
Illustration
 Release and remove the suction head.
back.
 Fit new paper filter bag.
Replacing the disposal bag
Illustration
 Release and remove the suction head.
 Attach the new disposal bag.
tainer.
 Insert and lock the suction head.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.
22
Troubleshooting
DANGER
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
 Turn on the appliance.
Suction turbine turns off
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replace filled paper filter bag.
 Replace the filled disposal bag.
 Ensure the filter cover properly locks
into place.
 Replace the flat pleated filter.
 Test the electrical tool connection.
Dust comes out while vacuuming
Illustration
 Check/correct the correct positioning of
the flat fold filter.
 Replace the flat pleated filter.
- 7