Device elements
1 Electrodes
2 Suction hose
3 Cable hook
4 Air outlet, working air
5 Suction head lock
6 Universal adapter
7 Air inlet, motor cooling air
8 Dirt receptacle
9 Suction head
10 Steering roller
11 Suction support
12 Connection bushing
13 Floor nozzle (not included in the delivery)
14 Suction pipe (not included in the delivery)
15 Rotary switch for suction hose cross
section
16 Carrying handle
17 Filter cover
18 Scale of the suction hose cross section
19 Elbow (not included in the delivery)
20 Rotary switch for suction output (min-
max)
21 Indicator lamp
22 Socket
23 Automatic filter dedusting
24 Main switch
25 Flat fold filter (PES)
26 Filter dedusting
27 Floor nozzle holder
28 Holder for crevice nozzle
29 Holder for suction pipes
30 Power cord
31 Nameplate
Symbols on the machine
M
M
!
WARNING: This unit contains hazardous
dust. Emptying and maintenance, includ-
ing the removal of the dust bag, may only
be carried out by someone who is familiar
with the unit and wearing suitable protec-
tive gear. Do not switch on the unit until the
complete filter system has been installed
and the function of the volume-flow control
has been tested.
PES
Safety instructions
DANGER
– When the outgoing air is carried back
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
of the fresh air volume flow (room vol-
ume V
x ventilation rate L
R
mum. Without a specific ventilation sys-
tem the following applies: L
– Only persons trained in the use of the
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
– This appliance contains harmful dust.
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.
– Do not use the appliance without the
complete filtering system.
– Please follow the safety regulations ap-
plicable to the materials that are to be
treated.
– 2
EN
Flat fold filter
Order No.
337.692
Flat fold filter (PES)
Order No.
369.829
Disposal bag
Order No.
340.766
) at maxi-
W
=1h
W
.
–1