Quality; Interruption Front Sensor; Date / Time; Check Of Binding - HellermannTyton AT2000 CPK Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 149

7.6.2 Quality

The
Q u a l i t y
setting corresponds to the quality of binding
and it can be set from
Level 1
(highest quality). The higher the level the longer the
cycle time, so the bundle has more time to settle.
Settings
Quality
Level 1
Level 2
Level 3
Back
f Use the Select button to select the quality level.
f Press the Enter button.
; The setting changes to the quality you selected.

7.6.3 Interruption front sensor

The
Interruption front sensor
decide how long the level sensor can remain busy
without the
Error, front cap
display.
This function is intended for use with the device integrated
into an automatic system.
Settings
Interruption front sensor
Level 1
0.0 sec.
Level 2
0.3 sec.
Level 3
0.5 sec.
Level 4
0.7 sec.
Level 5
0.9 sec.
Back
f Use the Select button to select the level.
f Press the Enter button.
; The setting changes to the level you selected.

7.6.4 Date / time

You can set the
Date / time
Settings
Date
1 8 F e b . 2 0 1 5
Clock time
1 0 : 2 3
f Use the Select button to change the date and time, as
applicable.
f Press the Enter button to conirm each digit.
; The setting changes to the option you selected.
time, à "Date / time" on page 14.
Date and time can also be synchronised with the PC date and
Operating Instructions • AT2000 CPK • 02-2017 • v02 • 106-29004
(lowest quality) to
Level 3
setting enables you to
message appearing on the
for process documentation.

7.6.5 Check of binding

The
Check of binding
setting enables you to decide
whether or not the Error, binding force
message appears on the display,
.
page 25
Settings
Check of binding
OFF
Error notification
Acknowledgement
f Use the Select button to select the option of your choice.
f Press the Enter button.
; The setting changes to the option you selected.
Setting
Meaning
OFF
The Error, binding force message does
not appear on the display.
Error notiication
The Error, binding force message
appears when applicable but does not require
conirmation.
Conirmation
The Error, binding force message
appears when applicable and requires
conirmation. The next binding is not possible
until the trigger has been pulled to conirm the
message.
7.7

Contact menu

The
Contact
menu shows you the current website with
country-speciic contact data.
Contact
www.HellermannTyton.com
Service menu
à "Display messages" on
14
Tabla de contenido

Solución de problemas

loading

Productos relacionados para HellermannTyton AT2000 CPK

Este manual también es adecuado para:

106-00000

Tabla de contenido