6
Commissioning and operation
Contact type
NC contact
NO contact
Tab. 5
Switching status of microswitch
6.2.2
Checking the manual release function
)
Note!
| The manual release is designed for operation using a Bowden cable.
| The braking circuits can only be released electrically.
}
Danger!
The drive system must be load−free. The motor must not rotate.
Fig. 16 Turning direction of the lever
1. Motor and brake deenergised.
2. Suspend bowden cable (not included in the delivery package) and pull with approx.
800 N.
– The rotor must rotate freely. A small residual torque is permissible.
3. Release the lever.
– Torque must be available!
The preparations for commissioning are completed.
Connection
Brake released
yes
black / grey
no
yes
black / blue
no
j | BA 14.0197 | 11/2010
i
Microswitch closed
no
yes
yes
no
BFK464−XX−S−014.iso/dms