j | BA 14.0197 | 11/2010
4
Mechanical installation
(
Fig. 13 Dimension "s
Type
BFK464−18S
BFK464−19S
BFK464−20S
BFK464−20S.1
BFK464−25S
BFK464−28S
}
30
Stop!
Before adjusting dimensions "s", check air gap "s
"s
" (^ 15) (^ 23). During air gap adjustment, the brake is not
Lürated
energised.
BFK464−XX−S−004a.iso/dms
" and "s"
Lü
1.1 Stator
+0.05
s
Lürated
0.4
0.5
Danger!
Brake may fail
If the manual release is not adjusted correctly the brake may fail.
Possible consequences:
| Severe injuries or material damage.
Protective measure:
| Observe dimension "s".
Lü
2
Armature plate
[mm]
" and, if necessary, adjust to
BFK464−XX−S−015.iso/dms
6
Flange
+0.1
s
[mm]
5.3
6.5