Calling Memorized Scenes; Interruption Of A Current Crossfading; Noting Down The Next But One Scene; Scene Sequences - IMG STAGELINE DMX-1440 Manual De Instrucciones

Ocultar thumbs Ver también para DMX-1440:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
pression of the scene to be memorized, slide
this fader fully upwards to the maximum
position .
2) Select the memory bank (the present bank is
displayed in the top left corner of the display,
e . g .
):
Bk01
a) either stepwise with the cursor keys
and
(23) or
b) press the button BANK /AUDIO (27) and
then directly enter the two-digit number
with the numerical keys (2), e . g . for bank
4, the buttons 0 and 4 (observe the lower
lettering of the buttons) .
3) Press the button STORE / PRG (22):
is indicated in the display .
Scene: [?]
4) If required, the adjustments of the control
channels can still be changed now . However,
for the quick reset of all values to zero, it is
possible to press the button DELETE (24) in
this case .
5) Press the numerical key (2) under which the
scene is to be memorized . Pay attention
to the upper lettering 1 – 12 . The indica-
tion
Store Scene: [?]
For cancel the memory procedure, press
the button STORE / PRG . The indication
Store Scene: [?]
in this case .
6) For memorizing further scenes, repeat the
steps 1) to 5) . In the table on page 68 or
in a copy of this, all scenes can be entered .
Notes:
a When memorizing a scene, only the values ad-
justed with the sliding controls (14) and the control
lever (18) are memorized . Actuating the buttons
FULL ON  (28), BLACKOUT (29), or a flash but-
ton (12) does not affect the storage, even if the
DMX units react correspondingly .
b The scene 01 of the bank 01 is automatically sent
to the output each time the unit is switched on .
For this reason, a suitable basic illumination should
be memorized for this scene .

6.2 Calling memorized scenes

1) First adjust the crossfading time (0 – 25 .4 s)
with the control C .F . TIME (7) or turn the
control to the position MAN for manual
cross fading with the crossfader (16) .
2) Select the memory bank into which the
desired scene has been stored (the current
bank is displayed on the top left, e . g .
a) either step by step with the cursor keys
and
(23) or
b) press the button BANK /AUDIO (27) and
then directly enter the two-digit number
with the numerical keys (2), e . g . for bank
4, the buttons 0 and 4 (pay attention to
the lower lettering of the buttons) .
3) Call the scene by pressing the correspond-
ing numerical key (2) . Pay attention to the
upper lettering 1 – 12 . The bank numbers
and scene numbers of the start scene (cur-
20
rent scene) and target scene (called scene)
are displayed: e . g .
4) If manual crossfading has been adjusted with
the control C .F . TIME, the LED HOLD / CROSS-
FADE under the button HOLD (3) lights up
after the selection of the scene number . For
crossfading, slide the crossfader (16) from
one end position to the other . The LED
HOLD / CROSSFADE flashes .
with the control C .F . TIME, the crossfading
starts after the selection of the scene num-
ber . The unit crossfades from the previous
scene to the newly selected one in the ad-
Store
justed crossfading time . Meanwhile, the LED
HOLD / CROSSFADE flashes and the display
shows the remaining time counting back-
wards until the target scene is reached .
Note: All control channels for which the function
Crossfade has been switched off when config-
uring (chapter 4 .4 .2), are immediately set to the
target value when starting the crossfading .
5) After reaching the target scene, only
this scene is displayed as a current scene
with bank number and scene number
is extinguished .
(e . g .
changed with the sliding controls (14) and
the control lever (18) . The bank number
is also extinguished
and scene number are replaced by an as-
terisk (
the output do no longer correspond to the
memorized scene values . For the next cross-
fading,
6) A scene called can be dimmed with the fader
MASTER LEVEL (15) and can be influenced
as in the direct mode by pressing the button
FULL ON (28), BLACKOUT (29), or one of the
flash buttons (12) .

6.2.1 Interruption of a current crossfading

If the control C .F . TIME is not in the position
MAN, it is possible to interrupt a current cross-
fading .
1) While crossfading, press the button HOLD
(3) . The LED below the button lights up . The
values sent to the output at the time of the
interruption are kept and serve as a start
scene for the next crossfading .
2) Select a new target scene, or for continuing
the interrupted crossfading, select the previ-
ous target scene again .
):
Bk13
3) For starting or continuing the crossfading,
 
press the button HOLD again .

6.2.2 Noting down the next but one scene

If another scene is selected while crossfad-
ing, this scene is noted down . After crossfad-
ing, the hold mode is activated and the LED
HOLD / CROSSFADE under the button HOLD (3)
lights up . For crossfading to the scene noted
down, press the button HOLD or in case of
manual crossfading slide the crossfader (16) to
the other end position .
01/06 Ɗ04/12
If a crossfading time has been adjusted
) . The current scene can be
04/12
) because the values now sent to
*
is displayed as a start scene .
01/00

7 Scene Sequences

.
From the scenes previously memorized, up to
120 scenes can be compiled to a scene se-
quence in any desired order and memorized .
60 different sequences can be memorized .
These may run manually, time-controlled, or
controlled by an audio signal in forward or
backward direction .

7.1 Reprogramming or changing scenes

7.1.1 Selecting a sequence number

1) Press the button SEQUENCE (26) . Next to
the button, the green LED RUN lights up and
the display shows
. However, the configuration menu
quence
must not be called [to exit it, press the but-
ton ESC / SETUP (21)] or the hold mode must
not be activated [to switch it off, press the
button HOLD (3)] .
2) Press the button STORE / PRG (22) . The green
LED is extinguished and the red LED PRG
lights up .
3) Directly enter the two-digit sequence number
with the numerical keys (2), e . g . for sequence
7 the buttons 0 and 7 (pay attention to the
lower lettering of the buttons) . Information
on the selected sequence is displayed:
Seq xx is blank!
(not programmed) sequence number
or e . g .
Seq11 014St +CFT
quence No . 11 which currently consists of
14 steps with individual crossfading time
in each case .
In case of wrong inputs, go back one
operating step with the button ESC / SETUP
(21) and enter the number again .
7.1.2 Deleting and reprogramming
a sequence
1) If the selected sequence number is in used,
the existing sequence can be deleted:
a) Press the button DELETE (24) . The ques-
tion
Clear Seq?
b) To delete the sequence, press the button
12 / YES (2) or to interrupt the deleting
process, press the button 11 / NO .
2) If
Seq xx is blank!
possible to start the programming of a new
sequence . The display asks in the second
line
CF Time/Step?
type must be determined:
a) For memorizing also different crossfading
times for the individual steps with the new
sequence, press the button 12 / YES . When
running the sequence later, the respective
crossfading times between the scenes are
kept . In this case, a series of 60 scenes as
a maximum can be memorized for the
sequence .
b) If it is desired that the crossfading time be-
tween the scenes is adjustable with con-
trol C .F . TIME (7) when running the new
sequence later, press the button 11 / NO .
As no times are memorized with this se-
quence type, it is possible to compile a
series of 120 scenes as a maximum .
3) Now enter the two digit bank number and
scene number of the first scene with the
numerical keys (2) . The input is displayed
behind
Seq xx St001
inputs, go back one operating step with the
,
Seq__
Select Se-
in case of an unused
for the se-
is displayed .
Y/N
is displayed, it is
. First the sequence
. In case of incorrect
Tabla de contenido
loading

Este manual también es adecuado para:

38.1980

Tabla de contenido