Table 3: Nozzle dimensions
Equipment model
Supply
gas type
G20
(20mbar)
G25
(20mbar)
G25
(25mbar)
G30
(28-30/37mbar)
G30
(50mbar)
GB
Primary burner air adjustment
1 - Loosen the base (B) fastening
screw.
2 - Rotate the base to adjust slot
dimension (C) (see table data).
3 - Tighten the base fastening
screw.
4 - Reassemble the burners.
5 - Reassemble the drain conduit ,
the grill supports , the lava
stone support grills and the
cook grills.
B/50
Burner
Pilot
nozzle
injector
diameter
diameter
3 x 1,35mm 1 x 0,30mm 6 x 1,35mm 2 x 0,30mm 8 x 1,35mm 2 x 0,30mm
3 x 1,55mm 1 x 0,30mm 6 x 1,55mm 2 x 0,30mm 8 x 1,55mm 2 x 0,30mm
3 x 1,45mm 1 x 0,30mm 6 x 1,45mm 2 x 0,30mm 8 x 1,45mm 2 x 0,30mm
3 x 0,92mm 1 x 0,20mm 6 x 0,92mm 2 x 0,20mm 8 x 0,92mm 2 x 0,20mm
3 x 0,80mm 1 x 0,20mm 6 x 0,80mm 2 x 0,20mm 8 x 0,80mm 2 x 0,20mm
B/80
Burner
Pilot
nozzle
injector
diameter
diameter
- 16 -
LAVA STONE GRILLS
B/115
Burner
Pilot
nozzle
injector
diameter
diameter
B
C