3 609 929 B68/2008-11 | BT356
The required power at the tightening position
is calculated from the speed and max. torque:
×
×
P
M
2π
n
=
1
1
1
×
×
P
M
2π
n
=
2
2
2
For a two-stage tightening case, the power
supplied at the tightening position is
approximately that as shown in the following
figure:
P/W
Screwing in
P
2
P
1
t
1
Fig. 10:
Approximately the same power is calculated
for the power loss in the servo amplifier.
Example
The following figures are available:
M
= 3.6 Nm; n
= 240 rpm;
1
1
M
= 143 Nm; n
= 24 rpm.
2
2
,
×
×
P
=
3 6Nm
2π
240
1
×
×
P
143Nm 2π
24
=
2
Tighten
Base load
t
2
T
U
=
90W
---------
min
U
360W
=
---------
min
Bosch Rexroth AG
Calculation of power loss
An approximate power loss can be
calculated using the tables overleaf and the
following formulas.
Table 8:
Abbreviations for formulas:
h
Cycle time
P
Total of individual losses in the installed
G
components in accordance with Table 6
P
Screw-in power loss
1
P
Max. power loss during end tightening
2
t
Screw-in duration
1
t
Tightening duration
2
n
Number of channels
P
Power loss
v
Calculation of total power loss
×
×
P
T
+
n P
G
1
P
=
----------------------------------------------------------------------------------------------------
V
35/124
×
×
×
×
t
+
n 0.5 P
t
1
2
2
T