Commissioning - Bosch Rexroth BT356 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
3 609 929 B68/2008-11 | BT356
6

Commissioning

CAUTION
Risk of damage to persons
and property!
Commissioning of the BT356
card rack requires basic
mechanical and electrical
knowledge.
y
Only qualified personnel (see
"Personnel qualifications" on
page 24) are authorized to
commission the system.
CAUTION
Danger to life due to
insufficient emergency OFF
equipment!
Emergency OFF equipment must
be functioning and within reach in
all system modes. Release of the
emergency OFF equipment may
not result in an uncontrolled
system restart!
y
Always check the emergency
OFF chain before switching on
the system!
y
Further information on the
emergency OFF can be found
in the instruction manual for the
VM350 power supply module
(3 609 929 B32).
Bosch Rexroth AG
CAUTION
Overheating of the BT356 card
rack and its components!
Damage to the card rack and its
components from overheating
y
Always keep the air ways for
cooling the BT356 card rack
clear.
1. Insert the NK350/ NK350S network
coupler (if used).
2. Insert the modules.
3. Close any unoccupied slots with an
appropriate dummy panel.
4. Connect to the mains.
5. Check that all the connection lines and
modules are properly connected.
6. Check that the emergency OFF circuit is
functioning correctly before
commissioning the tightening system.
7. Configure, program and parameterize the
tightening sequences with the 350 -
BS350 operating system.
.
Table 11: Dummy panels
Dummy panel
Type
for
BP351
Servo amplifier
BP352
Controller and
servo amplifier
37/124
Order number
3 608 878 058
3 608 878 060
Tabla de contenido