8. MAINTENANCE

Before starting work on the pump, make sure that all power supplies to the pump have been
switched off and that they cannot be accidentally switched on.
Pump bearings and shaft seal are maintenance-free.
Motor bearing
Motors which are not fi tted with grease nipples are maintenance-free. Motor fi tted with grease
nipples should be lubricated with high-temperature lithiumbased grease. See the instruction on
the fan cover. In the case of seasonal operation (motor is idle for more than 6 months of the year).
It is recommended to grease the motor when the pump is taken out of operation.
Intall the pump according to the instruction makes pump work effectively and less maintenance.
-Mechanical seal auto adjust,interface between stationary ring and rotation ring lubricated and
cooled by the pumping liquid.
-Sliding bearing lubricated by the pumping liquid.

9. FROST PROTECTION

Pumps which are not being used during periods of frost should be drained to avoid damage.
Drain the pump by loosening the vent screw in the pump head and by removing the drain plug
from the base. Care must be taken to ensure that the escaping water does not cause injury to
persons of damage to the motor or other components. In hot-water installations, special attention
should be paid to the risk of injury caused by scalding hot water. Do not tighten the vent screw and
replace the drain plug until the pump is to be used again.
VERTINOX 1 2 3 4 5
Before replacing the drain plug in the base, screw the bypass valve out against the stop. Fill the
drain plug by tightening the large union nut followed by the bypass valve.

10. FAULT FINDING CHART

Before removing the terminal box cover and before any removal/dismantling of the pump. Make
sure the electricity supply has been switched off and that it cannot be accidentally switchde on.
www.proindecsa.com / [email protected]