OPC UA (internal)
OPC UA client application
OPC UA server application
OPC "classic" client (DA, DCOM-
based)
OUC (internal)
Any partner
Add-ons to CPU 1505SP (F/T/TF), CPU 1507S (F), CPU 1508S (F) Version 2.6
A5E45929273-AD, 07/2019
Special features
Supported communication methods
•
–
Data access to any (configured) data
–
Method call
Requirement
•
–
You have enabled OPC UA.
Addressing the CPU via internal OPC UA client application
•
–
IP address: IP address of the runtime communication interface
–
IP port: Default
Supported communication methods
•
–
Data access to any (configured)
–
DataMethod Call
Requirement
•
–
You have enabled OPC UA.
Addressing internal server application via CPU
•
–
IP address: IP address of the Siemens RT-VMM network adapter
–
IP port: Default
Via OPC Wrapper applications under Windows (products from other manufacturers
are available)
Special features
Via PC communication interface
Supported communication methods
•
–
TCP programmed
–
UDP programmed
–
Note: Secure OUC communication is not possible over the PC communication
interface.
Addressing of the internal partner via the CPU
•
–
HW ID: 59 (PC communication interface)
–
IP address: IP address of one of the Windows Ethernet interfaces (not: local
host)
–
Port number: As defined
Addressing the CPU via the internal partner
•
–
IP address: IP address of one of the Windows Ethernet interfaces
–
Port number: As defined
Via runtime communication interface
Supported communication methods
•
–
TCP programmed
–
UDP programmed
–
ISOonTCP programmed
Addressing of the internal partner via the CPU
•
–
HW ID: 0
–
IP address: Siemens RT-VMM network adapter
–
Port number: As defined
Addressing the CPU via the internal partner
•
–
IP address: Runtime communication interface
–
Port number: As defined
23