Country GB (Great Britain)
Appliance
Model
Number
SG14
NAT
G20
LP
G31
SG14R
NAT
G20
LP
G31
SG14T
NAT
G20
LP
G31
SG18
NAT
G20
LP
G31
SG14C
NAT
G20
LP
G31
1) Following the Fryer Start-up and Shut Down instructions following in this manual, shut the appliance off and
allow the appliance to cool to room temperature. Insure that gas supply shut-off valve (located on the gas supply
pipe before the fryer operating gas valve) is in the "OFF" position. Remove main burners.
2) Remove all burner orifices and replace them with the appropriate orifices for the new gas type (refer to Table 1
for proper orifice size, that will match gas type conversion). Make sure that an approved gas sealant is applied to
the orifice threads before installing the orifices to the main burner manifold (remove burners if necessary to
replace orifices).
NOTE: If unit is being converted from LP to Natural gas or Natural to LP gas, the pilot orifice and regulator (on
gas valve) must also be replaced with appropriate orifice and gas type regulator.
3) If burners were removed, reinstall them and turn gas supply shut-off valve to the "ON" position. Refer to lighting
instructions and relight the appliance. With burners on, check for any gas leakage around the orifices.
4) With main burners operating, check burner manifold pressure and insure that proper gas pressure is supplied to
the burner system (refer to Table 2 for pressure settings). Adjust if necessary.
5) Finally, apply the gas type conversion label, provided with the conversion kit, just below the fryer data plate on
the fryer door inside panel.
Table 1 Orifice Tips
Model
G20
SG14
#41
SG14R
#39
SG14T
#43
SG18
#41
KC14
#43
GAS SPECIFICATION TABLE
33
II
2H3P
33
36
II
2H3P
36
15 (X2)
II
2H3P
15 (X2)
40
II
2H3P
40
26.5
II
2H3P
26.5
CONVERSION INSTRUCTIONS FOR PITCO SG SERIES FRYERS
Gas Type
G25
G31
#37
#53
#36
.0625
#41
1.45mm
#38
#53
#41
#54
29.7
20
10
30.4
50/37
25.4
32.4
20
10
33.1
50/37
25.4
13.5 (X2)
20
10
13.8 (X2)
50/37
25.4
36.0
20
9
36.8
50/37
25.4
23.9
20
10
24.4
50/37
25.4
Table 2 Burner Pressure (mbar)
Model
G20
G25
SG14
10
SG14R
10
SG14T
10
SG18
9
2
#41
N22
Yes
#53
LP16
Yes
#38
N22
Yes
0.0625
LP16
Yes
#43
N22
Yes
1.45mm
LP16
Yes
#41
N22
Yes
#53
LP16
Yes
#43
N22
Yes
#54
LP16
Yes
Gas Type
G31
10
25.4
10
25.4
10
25.4
10
25.4
3.1
1.2
3.4
1.4
1.4
.6 (X2)
3.8
1.5
2.5
1.0