Roland JX-305 Manual Del Usuario página 239

Ocultar thumbs Ver también para JX-305:
Tabla de contenido
Data Request 1 RQ1
This message requests the other device to transmit data. The address and size indicate the
type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it is able to
transmit data, and if the address and size are appropriate, the requested data is
transmitted as a Data Set 1 (DT1) message. If the conditions are not met, nothing is
transmitted.
The model ID of the exclusive messages used by this instrument is 00 0BH.
status
data byte
F0H
41H, dev, 00H, 0BH, 11H, aaH, bbH, ccH, ddH,
ssH, ttH, uuH, vvH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H–1FH)
00H
model ID (JX-305)
0BH
model ID (JX-305)
11H
command ID (RQ1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
ssH
size MSB
ttH
size
uuH
size
vvH
size LSB
sum
checksum
F7H
EOX (End Of Exclusive)
* For the address, size, and checksum, refer to "Examples of system exclusive messages
and calculating the checksum" (p. 253).
* This message is not received if the Rx.System Exclusive Switch Switch parameter is
OFF.
Data Set 1
DT1
This message transmits the actual data, and is used when you wish to set the data of the
receiving device.
status
data byte
F0H
41H, dev, 00H, 0BH, 12H, aaH, bbH, ccH, ddH, eeH, ... ffH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H–1FH)
00H
model ID (JX-305)
0BH
model ID (JX-305)
12H
command ID (DT1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
eeH
data: The actual data to be transmitted. Multi-byte data is transmitted in the
order of the address.
:
:
ffH
data
sum
checksum
F7H
EOX (End Of Exclusive)
* For the address, size, and checksum, refer to "Examples of system exclusive messages
and calculating the checksum" (p. 253).
* Data whose size is greater than 128 bytes should be divided into packets of 128 bytes
or less and transmitted. Successive "Data Set 1" messages should have at least 20 ms of
time interval between them.
* This message is not received if the Rx.System Exclusive Switch parameter is OFF.
The only GS exclusive messages received by the JX-305 are Scale Tune settings (p. 253).
Data Set 1
status
data byte
F0H
41H, dev, 42, 12H, aaH, bbH, ccH, ddH, ... eeH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H–1FH)
status
42H
model ID (GS)
F7H
12H
command ID (DT1)
aaH
address MSB
bbH
address
ccH
address LSB
ddH
data: The actual data to be transmitted. Multi-byte data is transmitted in the
order of the address.
:
:
eeH
data
sum
checksum
F7H
EOX (End Of Exclusive)
* This message is not received if the Rx.System Exclusive Switch parameter is OFF.
In addition to conventional system exclusive messages, the JX-305 also uses special system
exclusive messages for operations which require realtime handling, such as knobs.
Data Set 1
status
data byte
F0H
41H, dev, 3AH, 12H, aaH, bbH, ccH, ddH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number (Roland)
dev
device ID (dev: 10H–1FH)
3AH
model ID (JX-305 Quick)
12H
command ID (DT1)
aaH
address (Status/Channel)
bbH
address/Data H
ccH
Data L
status
ddH
Data E
F7H
sum
checksum
F7H
EOX (End Of Exclusive)
* For the address, size, and checksum, refer to "Examples of system exclusive messages
and calculating the checksum" (p. 253).
* Transmission of consecutive addresses is not possible.
* This message is not received if the Rx.System Exclusive Switch parameter is OFF.
2. Data transmission
(sound source section)
Channel Voice messages
Note Off
status
2nd byte
8nH
kkH
Note On
status
2nd byte
9nH
kkH
vv=Note On velocity:
Control Change
* By selecting a controller number that corresponds to the setting of the Control Pedal
Assign parameter, you can transmit any desired control change.
DT1
DT1
3rd byte
vvH
3rd byte
vvH
01H - 7FH (1 - 127)
status
F7H
status
F7H
239
Tabla de contenido
loading

Tabla de contenido