Air-blast and injection unit
6 Installation
6.1 Installation
6.2 Pneumatic connection
6.3 Electrical connection
For a trouble-free operation, the oil repository must always point upwards.
see Fig. 6 Mounting bracket on page EN-8
The device is horizontally fastened by means of 2 screws M6 and the mounting
bracket on a fixed surface.
NOTE
The Air-blast and injection unit is only safe for operation and
functioning if the present arrangement of the device and the specified flow
direction are complied with.
The pneumatic connection is carried out with a suitable connecting hose (inner
width 11 mm to the hose nozzle of the directional valve.
1
Air-blast hose
Fig. 7
Pneumatic connection
The air-blast hose (1) of the ROBO hose assembly is screwed to the outlet.
The electrical connection at the 2/2 directional valve is done directly at the
device socket using a suitable cable.
6 Installation
1
EN - 9