Electrical Requirements - Kohler sok K–1188 Guia De Instalacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Important Product Information (cont.)

Electrical Requirements

The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI). The GFCI protects against
line-to-ground shock hazard. Use a 240V, 15A, 60 Hz dedicated service.
An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of
electrical shock, this terminal must be connected to the grounding means provided in the electrical supply
panel with a conductor equivalent in size to the circuit conductors supplying this equipment.
Install this unit in accordance with the Canadian Electric code, Part I.
Kohler Co.
3
1005288-2-D