12. PROBLEM IDENTIFICATION

PROBLEM
1. No start
2. Power loss.
3. Engine rotates at
the minimum or 
operates irregularly
4. Excessive vibrations
5. Loss or slowing of 
thrown snow
6. Traction not working.
If problems persist after having performed the above operations, contact your dealer.
PROBABLE CAUSE
Ignition key not inserted.
No fuel.
Choke disconnected
Primer bulb not pressed
Engine flooded
Spark plug damaged
Spent fuel
Water in fuel
Too much snow thrown
Fuel tank cap covered with ice or snow. Remove ice or snow from over 
The choke is engaged
Spent fuel
Water in fuel
Carburettor needs replacing
Loose parts or auger or rotor damaged. Tighten all the fastening devices.
Handle not correctly positioned.
Blocked discharge chute.
Auger blocked.
Traction drive command cable 
not correctly adjusted.
Frequency
First time
-
10 hours / every season
-
25 hours / every season
-
100 hours / every season
-
5 hours / after each use
5 hours
50 hours / every season
Insert the ignition key.
Fill the tank with quality, pure fuel.
Engage the choke.
Press the primer bulb
Wait a few minutes before starting. 
Do not press the primer bulb 
and disconnect the choke.
Contact the authorised assistance centre.
Contact the authorised assistance centre.
Contact the authorised assistance centre.
Reduce speed
and around the tank cap
Disconnect the choke.
Contact the authorised assistance centre.
Contact the authorised assistance centre.
Contact the authorised assistance centre.
Replace the damaged parts in the 
authorised assistance centre.
Ensure the handle is fastened in its position.
Clean the discharge chute.
Remove any dirt or foreign 
bodies from the auger.
Contact the authorised assistance centre.
EN - 14
An then after
REMEDY
Paragraph
7.8
***
***
7.3.1
7.3.2
Tabla de contenido