MAINTENANCE
PILOT ARC LEAD CONNECTION AND STRIP INSULATION
Slide insulator onto lead.
Attach knife connections.
Center insulator
over connection
A. PILOT ARC LEAD CONNECTION DETAIL
Power cable connection
Pilot arc
wire lead
Insulator
Strip insulator
Vinyl tape each end
B. STRIP INSULATION DETAIL
- - 40 - -
Fold back leads by
turning the insulator
end for end.
Tape leads to insulator
Place the insulator between
the power cable connection
and the black pilot arc lead.
Tape in place as illustrated.
Black wire lead