6. For Natural Gas ranges, note the original position of
the slot in the valve screw. This can be done by
engaging the screwdriver's blade in the screw slot and
marking the screwdriver's handle to indicate the
starting position of the valve screw. With the
screwdriver still engaged, carefully rotate the valve
screw counter-clockwise (CCW) 1/4 turn (or 90
degrees) from its original position. Repeat this
procedure to adjust the setting for each valve screw.
For LP Gas ranges or an appliance that has been
converted to LP Gas, adjustment is rarely necessary.
7. Turn on the gas and electrical power to the appliance.
Reevaluate the flames. Repeat Steps 1 through 6 if
further adjustment is necessary.
English 3