Heath Zenith DualBrite 4115 Instrucciones De Instalación página 6

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TESTING
1. Turn on the circuit breaker and light
switch.
Note: Sensor has a 1
before it will detect motion. When first
turned on wait 1
2. Switch the on-time to TEST position and
D
B
switch to the OFF position.
®
ual
rite
TEST 1 5 10 MIN
ON-TIME
Avoid aiming the control at:
• Pools of water or objects that change tem-
perature rapidly, such as heating vents and
air conditioners. These heat sources could
cause false triggering.
• Areas where pets or traffic may trigger the
control.
• Nearby large, light-colored objects reflect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.
6 ft.
(1.8)
Maximum Range
/
minute warm up period
1
2
/
minutes.
1
2
OFF 3 6 DUSK TO
HOUR DAWN
30 ft.
(9.1m)
Maximum
Coverage Angle
The detector is less sensitive to motion directly
towards it and more sensitive to across motion.
Motion
Least Sensitive
3. Walk through the coverage area noting
where you are when the lights turn on. Move
the sensor head left or right to change the
coverage area. Note: Grasp the sensor only
as shown and turn the entire sensor. Any
other method may damage the sensor. Do
not force it past the stops.
150°
Rotating Sensor Head to Change Coverage
4. If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
5. Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5,
or 10 minutes).
6. Set the amount of time after dusk you want
the lights on accent level.
6
Motion
Sensor
Most Sensitive
Area
206872-01