Electrical Connection - Moretti Forni NordCap F100E Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

cm from the right side wall (fig.7). This distance of 50 cm is essential
in order to guarantee access during maintenance operations.
Take into account that for certain cleaning/maintenance operations, the
distance needs to be greater than stated here and therefore,
consider the possibility to be able to move the oven.
2.5
CONNECTIONS
2.5.1
STEAM
AND
CONNECTION
WARNING!
Connection of the steam exhaust must only be
carried out by specialised personnel.
The steam exhaust is on the top of the oven and needs to be connected
to a flue or to the outside.
NOTE:
In case there is a hood over the oven , connect it as in
Fig. 8a using a pipe with a minimum diameter of 150 mm.
If there is no hood over the oven , connect it as in Fig. 8b a pipe
with a minimum diameter of 110 mm for F45E, F50E and F100E.
THE SMOKE EXHAUST FITTING IS PROVIDED (item Z in
Fig. 8b) THIS MUST ONLY BE USED WHEN THERE IS NO
OVEN HOOD PRESENT.
The exhaust pipe must be inserted into the oven exhaust outlet. Any
extensions need to be fitted so that the
top pipes enter the bottom ones.
In case of installation of the special extractor, this will remain in
position, as shown in Fig.23
NOTE:
If the vapour is not exhausted properly, this will affect
the baking results; if necessary, assess the possibility to install the
relevant extractor.
The fittings for the condensation drainage pipes are on the back,; for
the F45E,F50E and F100E oven,item G in fig. 12; proceed to make the
connections using pipes with a suitable diameter and secure them with
pipe clamps, connecting them to a suitable outlet.
2.5.2

ELECTRICAL CONNECTION

WARNING!
Electrical connection must only be carried out
by specialised personnel, in compliance with current local
requirements
of CEI (Electric Quality Assurance Corporation.)
Before starting the connection procedure, check that the earthing
system is provided in accordance with European EN standards.
Before starting the connection procedure, check that the main power
switch for the supply to which the oven is to be connected has been
turned to the "off" position and the wires connecting to the power
socket have been disconnected.
The rating plate contains all the information necessary for proper
connection.
2.5.2.1 ELECTRICAL CONNECTION OF THE BAKING
CHAMBER
WARNING!
Each baking chamber must be fitted, by the
customer, with a main thermo-magnetic differential type four-pole
switch, with a threshold Id of 0.03A suitable for the values shown
on the plate, to allow the single appliances to be disconnected from
the mains, that provide full disconnection under overvoltage
category III conditions.
NOTE:
The device selected should be in the immediate vicinity
of the appliance and within easy access.
The baking chamber is delivered with the required voltage indicated on
the rating plate (fig. 2). When connecting to the power mains, it is
necessary to fit a plug that complies with the standards and regulations
in force.
According to the voltage for which the oven has been made, which is
stated on the rating plate (fig.2), fit a plug as listed here below:
Voltage
Plug
F45E
F50E
V400 3N
16 A
16 A
3P + N +
V230 3
32 A
32 A
3P +
V230 1N
63 A
63 A
2P +
F45E-F50E-F100E
To carry out electrical connection, remove the protective cover located
on the rear side of the baking chamber (fig. 10). The connection cable
must be supplied by the installer.
CONDENSATION
EXHAUST
F100E
32 A
63 A
Insert a cable with a suitable cross-section (see technical data, table 1)
into the relevant cable gland (Item A-fig.11) and connect it to the
terminal board, as shown in
figure 16.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ±5%.
WARNING!
earthed. To do this, use the yellow/green wire and the connection
cable only. The flexible wire for connection to the power supply
must have characteristics at least equal to the model with rubber
insulation HO7RN-F and must have a rated section suited to the
maximum absorption (see technical data in TAB.1)
These appliances must also be included in the equipotential system.
The terminal provided for this purpose is located at the back (fig.11
part.B).It
is
marked
EQUIPOTENTIAL CONNECTION.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ± 5%.
2.5.2.2. LEAVENING
CONNECTION
WARNING!
two-pole switch with fuses or an automatic switch suitable for the
values shown on the plate.
NOTE:
The device selected should be in the immediate vicinity
of the appliance and within easy access.
The leavening compartment is delivered with a voltage of 230V 1N
50/60 Hz, as indicated on the rating plate (fig.2).
To carry out electrical connection, remove the protective cover located
on the left hand rear side of the compartment (fig.10).
The connection cable must be supplied by the installer.
The flexible wire for connection to the power supply must have
characteristics at least equal to the model with rubber insulation
HO7RN-F, and it must have a rated section suited to the maximum
absorption (see technical data in TAB.1.) .
When connecting to the power mains, it is necessary to fit a plug that
complies with the standards and regulations in force.
Insert a cable with an adequate cross-section (see technical data in
TAB.1) into the cable gland provided (item A - fig.11) and then
connect it to the terminal board as illustrated in figure 16.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ±5%.
WARNING!
earthed.
A special earth terminal has been provided for this purpose on the
connection terminal board (fig. 16). It is marked with the earth symbol
and the earth wire must be connected to it.
These appliances must also be included in the equipotential system.
The terminal to be used for this purpose is located at the back of the
appliance (fig.11
item B). It is marked with the symbol TERMINAL FOR THE
EQUIPOTENTIAL SYSTEM
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ± 5%.
2.5.3.
CONNECTION TO THE HYDRAULIC NET
Connection to the water supply mains must comply with the
regulations in force and flexible pipes for the connection to the water
supply network must
UK/3
It is essential that the appliance be properly
with
the
symbol
TERMINAL
COMPARTMENT
The compartment must be fitted with a main
It is essential that the appliance be properly
.
FOR
ELECTRICAL

Capítulos

Tabla de contenido
loading

Productos relacionados para Moretti Forni NordCap F100E

Este manual también es adecuado para:

493500600100

Tabla de contenido