Specifications
XPS-10
Measurement
0.3 - 10 m
Range
(1 - 33 ft)
Frequency (kHz)
44
Beam Angle
12
Location
indoor/outdoor indoor/outdoor
Maximum
2000
Altitude (m)
-40 to 95 C
Ambient
Temperature
(-40 to 203 F)
8 bar
Pressure
(120 psi)
Pollution Degree
4
PVDF
Housing
1" NPT or
BSP conduit
Mounting
connection
•
•
•
•
Options
2-wire twisted pair/braided and
foil shielded, 0.5mm² (20 AWG),
Cable
PVC jacket
0.8 kg
Weight**
(1.7 lb)
Maximum
365 m
Separation
(1200 ft)
Supply Source
CE***, CSA, FM, CENELEC/ATEX, INMETRO: See nameplate or consult Siemens Milltronics for current
Approvals
*
Universal flange fits ANSI, DIN, and JIS standards.
** Approximate shipping weight of transducer with standard cable length.
*** EMC performance available upon request.
Page EN-8
XPS/XCT Series Transducers – OPERATION MANUAL
All manuals and user guides at all-guides.com
XPS-15
XPS-30
0.3 - 15 m
0.6 - 30 m
(1 - 50 ft)
(2 - 100 ft)
44
30
6
6
Environmental
indoor/outdoor
2000
2000
-40 to 95 C
-40 to 95 C
(-40 to 203 F)
(-40 to 203 F)
8 bar
Europe: 0.5 bar
(120 psi)
N. America: 15 psi
4
4
Construction
PVDF
PVDF
1" NPT or BSP
1-1/2" NPT or BSP
conduit
conduit
connection
connection
factory bonded to suit ANSI, DIN, and JIS standards
polyethylene foam facing for dusty or steamy environments
submergence shield, where flooding can occur (available only for XPS-10,
XPS-15)
split flange for field mounting to suit ANSI, DIN, and JIS standards (not
available for XPS-40)
• 2-wire twisted pair/
braided and foil shielded,
0.5mm² (20 AWG), PVC
jacket
Maximum separation: 100 m
(330 ft)
• RG-62 A/U coax
Maximum separation: 365 m
(1200 ft)
1.3 kg
4.3 kg
(2.8 lb)
(9.5 lb)
365 m
365 m
(1200 ft)
(1200 ft)
Transducers shall only be supplied by Siemens Milltronics certified controllers
XPS-40
XCT-8
0.9 - 40 m
0.6 - 8 m
(3 -130 ft)
(2 - 26 ft)
22
44
6
12
indoor/outdoor
indoor/outdoor indoor/outdoor
2000
2000
-40 to 95 C
-40 to 145 C
(-40 to 203 F)
(-40 to 293 F)
Europe: 0.5 bar
8 bar
N. America: 15 psi
(120 psi)
4
4
PVDF
Standard: PVDF
Optional: Universal* sized
flange available with PTFE
1-1/2" NPT or BSP
1" NPT or BSP
conduit
conduit
connection
connection
8 kg
0.8 kg
(18 lb)
(1.7 lb)
365 m
365 m
(1200 ft)
(1200 ft)
approvals.
XCT-12
0.6 - 12 m
(2 - 40 ft)
44
6
2000
-40 to 145 C
(-40 to 293 F)
8 bar
(120 psi)
4
facing
1" NPT or BSP
conduit
connection
Silicon Jacket
1.3 kg
(2.8 lb)
365 m
(1200 ft)
A5E32282889