VIII. TROUBLE SHOOTING:
Some models may use R-290 (Propane) as a refrigerant.
Service and repair must be performed by qualified refrigeration technicians familiar with applicable safety standards for
flammable refrigerants. Technicians must use appropriate personal protective equipment and follow applicable safely pre-
cautions to avoid risk of fire or explosion.
Service and repair must be performed in well ventilated and unconfined area, away from any ignition sources.
All system components must be replaced with like components. Factory recommends to use exact make and models to as-
sure the consistent performance and to minimize the risk of possible ignition due to incorrect parts. In case of uncertainty
or parts unavailability, contact Traulsen technical assistance at 800-825-8220.
PROBLEM
1. Condensing unit fails to start.
2. Condensing unit operates for prolonged periods or
continuously.
3. Food Compartment is too warm.
4. Food Compartment is too cold.
5. Condensation on exterior surface.
6. Compressor hums & does not start.
IX. SERVICE/WARRANTY INFORMATION:
Before making contact, please make sure you have model and serial number of the unit. Amp plate with information needed is
located on the unit.
Please visit our website at www.traulsen.com for additional service and parts information. From our home page click on the
SERVICE & PARTS tab, and select one of the following:
HOURS OF OPERATION:
Monday thru Friday 7:30 am - 4:30 pm CST
Quality Refrigeration
a. Check if cord & plug has been disconnected.
a. Are door(s) or drawer(s) closing properly?
b. Dirty condenser or filter. Clean properly.
c. Evaporator coils iced. Needs to defrost.
a. Check door(s) or drawer(s) and gasket(s) for proper seal.
b. Check if a large quantity of warm food was recently added or the door was kept open for a long period of time.
c. Microprocessor control setting is too high, readjust.
a. Check if a large quantity of very cold or frozen food has recently been added. Allow adequate time for the cabinet to
recover its normal operating temperature.
b. Adjust the microprocessor control to warmer setting, readjust.
a. Check door(s) or drawer(s) alignment & gaskets for proper seal.
b. Condensation on the exterior surface of the unit is perfectly normal during periods of high humidity.
c. Check perimeter heat setting and increase setting if <100.
a. Call for service.
Amp Plate
T
raulsen
4401 Blue Mound Road Fort Worth, TX 76106
Phone (800) 825-8220 Service Fax (817) 740-6757
www.traulsen.com
© 2015 Traulsen - All Rights Reserved
POSSIBLE SOLUTION
SERVICE FINDER
SERVICE PARTS MANUALS
OPERATOR MANUALS
WARRANTY REGISTRATION