II. OPERATION: (continued)
Hot Food Holding Cabinets
Are shipped in the Off position. To begin use, first press the ON/
OFF button
, and then adjust to the desired operating temperature
using the UP/DOWN
Hot Food Control
UP/DOWN Buttons
ON/OFF Button
G Series/Compact Cabinets
Are fully operational and no action is required to start. Please note,
most compacts are equipped with an electromechanical control.
Compact Cabinets (electromechanical)
The temperature is set at the factory but local conditions may neces-
sitate slight adjustment. The temperature control is located in the
front of the evaporator housing. To adjust, turn the adjustment screw
with a screwdriver a small amount at a time; turning clockwise low-
ers the temperature. An "OFF" position is fully counterclockwise
and interrupts power to the compressor and condenser fan only, not
the entire refrigerator.
III. CONTROL BASICS:
Customer Access
To adjust any of the control's operating features, enter the customer
access code. Use the code 0, A, 1 combined with the following:
Press the SET button. The display will read CUS (Customer Ac-
cess). Press the SET button. The display will show three zeros
with the left zero flashing, Press the SET button. The display will
show three zeros with the center zero flashing. Press the DOWN
ARROW key to sequence through F, E, d, C, b, A,...etc. When
you reach A press SET. The display will show zero, A, zero with
the right zero flashing. Press the UP ARROW key to sequence
through 1, 2, 3, 4, 5, 6, 7, 8, 9, A, b,...etc. When you reach 1 press
SET. The display will read SP (Thermostat Set Point). Press the
SET button to view and again to exit. You are now ready to adjust
the control. Listed below are the available parameters in the order
they appear, using the down arrow key on the controller, you can
use either the up or down arrow keys to scroll through the options.
Thermostat Set Point
Themostat Set Point Differential
Temperature Scale
Time (24-hour clock)
Date (month-day-year)
Daylight Savings
Start Manual Defrost
Defrost Lockout 1
Defrost Lockout 2
buttons.
Defrost Lockout 3
Defrost Lockout 4
Dew Point Compensation Factor
Room Temperature Offset
Audible Alarm Style
Cabinet Air Sensor Temp
Evaporator Coil Sensor
Liquid Line Sensor
Defrost Lockout Feature
Defrost lockouts will allow you to prevent defrost cycles from oc-
curring for two hours during a designated time. Up to four can be
set for any 24-hour period. Each of the lockout parameters covers
6-hours of the 24-hour clock.
NOTE: The 24-hour clock must be set for this feature to operate
at the correct time of day.
DL1/OFF
DL2/OFF
020 = 2:00 a.m. 080 = 8:00 a.m.
023 = 2:30 a.m. 083 = 8:30 a.m.
030 = 3:00 a.m. 090 = 9:00 a.m.
033 = 3:30 a.m. 093 = 9:30 a.m.
040 = 4:00 a.m. 100 = 10:00 a.m. 160 = 4:00 p.m. 220 = 10:00 p.m.
043 = 4:30 a.m. 103 = 10:30 a.m. 163 = 4:30 p.m. 223 = 10:30 p.m.
050 = 5:00 a.m. 110 = 11:00 a.m. 170 = 5:00 p.m. 230 = 11:00 p.m.
053 = 5:30 a.m. 113 = 11:30 a.m. 173 = 5:30 p.m. 233 = 11:30 p.m.
060 = 6:00 a.m. 120 = 12:00 p.m. 180 = 6:00 p.m. 240* = 12:00 a.m.
063 = 6:30 a.m. 123 = 12:30 p.m. 183 = 6:30 p.m. 243* = 12:30 a.m.
070 = 7:00 a.m. 130 = 1:00 p.m.
073 = 7:30 a.m. 133 = 1:30 p.m.
080 = 8:00 a.m. 140 = 2:00 p.m.
NOTE: First Enter Customer Access (see customer access)
When the control displays
down arrow key
until the control displays
or
Press the set button
off. Press the arrow keys
correct time is displayed, press the set button
the up or down arrow keys
or press the alarm cancel button to exit
30 seconds.

Setting The Clock

The internal time clock must be set in order for the data storage
memory to correctly log events and to allow any defrost lockout to
occur at the correct time of day. If the clock is not set, the control
assumes the time is 12 a.m. at the time power is supplied to the unit.
The hours on a 24-hour time clock read the following way:
H01 = 1:00 a.m. H07 = 7:00 a.m.
H02 = 2:00 a.m. H08 = 8:00 a.m.
H03 = 3:00 a.m. H09 = 9:00 a.m.
H04 = 4:00 a.m. H10 = 10:00 a.m. H16 = 4:00 p.m. H22 = 10:00 p.m.
H05 = 5:00 a.m. H11 = 11:00 a.m. H17 = 5:00 p.m. H23 = 11:00 p.m.
H06 = 6:00 a.m. H12 = 12:00 p.m. H18 = 6:00 p.m. H24 = 12:00 a.m.
NOTE: First Enter Customer Access (see customer access)
When the control displays
down arrow key
until the control display reads
SET
Press the Set button
right two numbers will be flashing. Use the arrow keys
set the hour. When the correct hour is displayed, press the Set
button
. The display will show
SET
two numbers will be flashing. Use the arrow keys
the minutes.
-2-
DL3/OFF
DL4/OFF
140 = 2:00 p.m. 200 = 8:00 p.m.
143 = 2:30 p.m. 203 = 8:30 p.m.
150 = 3:00 p.m. 210 = 9:00 p.m.
153 = 3:30 p.m. 213 = 9:30 p.m.
190 = 7:00 p.m. 010 = 1:00 a.m.
193 = 7:30 p.m. 013 = 1:30 a.m.
200 = 8:00 p.m. 020 = 2:00 a.m.
Thermostat Set Point, press the
. The display will show
SET
to set the start time. When the
. You can press
SET
to scroll to the next parameter
or leave inactive for
H13 = 1:00 p.m. H19 = 7:00 p.m.
H14 = 2:00 p.m. H20 = 8:00 p.m.
H15 = 3:00 p.m. H21 = 9:00 p.m.
Thermostat Set Point, press the
. The display will show
minutes. The right
clock.
Hours. The
to
to set
Tabla de contenido
loading

Este manual también es adecuado para:

G serie

Tabla de contenido