Troubleshooting (cont.)
Symptoms
11. The seal will not fully
inflate or the compressor
keeps turning on after
inflation.
Kohler Co.
Probable Causes
F.
Error code in controller has
been activated (beeping sound
heard).
G. The drain valve is not working.
H. The controller is not working.
A. One or both limit switches are
not making contact or are
damaged.
17
Recommended Action
F1. Reset the controller. To do this:
Lower the door.
Quickly tap the door switch
five times within 2 seconds.
For controllers date coded
before June, 2015, wait 3
seconds, then tap the switch 11
times within a 5 second span.
For controllers date coded after
June, 2015, raise the door into
the latched position.
The controller should beep
three to five times to indicate
the issue has been resolved,
then go quiet.
With the door in the down
position, confirm the error code
has been removed by pressing
the door switch one time. If the
controller continues to beep,
repeat the preceding steps until
the error code is cleared.
Once the error code is cleared,
identify and correct the
problem that caused the error
code. Begin troubleshooting
any problems with the bath by
running it through multiple fill
and drain sequences, and note
any symptoms.
F2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
G. Replace the drain valve or call the
Customer Care Center using the
information provided on the back
page of this manual.
H. Replace the controller or call
Customer Care Center using the
information provided on the back
page of this manual.
A1. Adjust the limit switch or switches
until contact is made.
A2. The limit switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
1128532-5-H