Package Contents; Description (Fig. A); Electrical Safety - DeWalt D23700 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
E N G L I S H

Package contents

The package contains:
1 Circular saw
1 Parallel fence
1 Saw blade wrench
1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or accessories
which may have occurred during transport.
• Take the time to thoroughly read and understand
this manual prior to operation.

Description (fig. A)

Your D23700 circular saw has been designed for
professional sawing of wood and plastic.
Abrasive cutting wheels are available for cutting
metal and stone.
1 On/off switch
2 Lock-off button
3 Front handle
4 Spindle lock
5 Dust extraction outlet
6 Saw shoe
7 Riving knife
8 Lower guard retracting lever
9 Lower guard
10 Saw blade
11 Bevel adjustment knob
12 Mark for bevel cut
13 Mark for straight cut
14 Depth adjustment knob
15 Parallel fence

Electrical safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 60745; therefore no
earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
28
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500
W, we recommend to fit a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
2
size is 1.5 mm
.
When using a cable reel, always unwind the cable
completely.
Also refer to the table below.
2
Conductor size (mm
)
0.75
1.00
1.50
2.50
4.00
Cable rating (Amperes)
6
10
15
20
25
.
Tabla de contenido
loading

Tabla de contenido