Sensitive edge with NC clean
contact (BAR)
- with the gate stopped, does not
allow the gate to open
- in opening disengages
- with the gate open, does not al-
low it to close and when released
will reset the pause time
- in closing disengages
8.2 KΩ balanced sensitive edge
(8K2)
Same behaviour as the NC sensi-
tive edge
Stop (STP)
- stops the gate
Interrupts the automatic closing
as per the logic stop setting from
stop (L12)
S(X)
Photocell closing checked
(PHC)
As per closing photocell but with
check
Photocell checked (PHT)
As per photocell but with check
Photocell opening checked
(PHC)
As per opening photocell but with
check
NC sensitive edge checked
(BART)
As per KΩ NC sensitive edge but
with check
8.2 KΩ balanced sensitive edge
checked (8K2T)
As per 8.2 KΩ sensitive edge but
with check
Control panel logic settings
Sub
Description
menu
Automatic closing
L1
Automatic closing off
Automatic closing on
Pause time
1 s (minimum time)
L2
180 s (maximum time)
Pedestrian pause time
1 s (minimum time)
L3
180 s (maximum time)
State on power up
Gate in closed position:
The first step-step command
opens the gate.
L4
Gate in open position:
The first step-step command
closes the gate. If automatic clos-
ing is on, after the pause time the
gate closes
Apartment block
Apartment block function off
Does not close and stop in opening
Does not close and stop in open-
L5
ing and pause
4
Does not close and stop in open-
ing, pause and closing
Rapid closing
Rapid closing function off
Rapid closing in gate mode:
The control panel starts to count
5
the clearance time (L7) from when
the closing photocell is released,
when the clearance time expires it
closes again.
Rapid closing in barrier mode:
6
The control panel starts to count
L6
the clearance time (L7) from
when the closing photocell is
released, and when the clearance
7
time expires it closes again. If
the closing photocell is occupied
again, it gives a stop command.
8
When released again it continues
with closing. The closing photocell
returns to normal operating after
9
complete closure.
Clearance time (adjustable at
intervals of 1 s)
Time after which the gate closes
L7
10
again if the rapid closing (L6) is on
Minimum clearance time
Maximum clearance time
Pre-flash
11
Flashing time of the flashing light
before the gate starts to move
L8
Pre-flash disabled
Values
3 s pre-flash
4 s pre-flash
(default)
5 s pre-flash
(ON)
Manned
OFF
Manned function off
ON
Step-step command disabled,
(30)
1
remote controls not working. The
control panel accepts only open
180
L9
and close commands
(20)
Emergency manned. In normal
1
standard operating conditions, with
180
the safety devices occupied it
(OP)
works as manned.
Step by step
CL
Step-step command operates in
2 steps:
open, close, open...
Step-step command operates in
L10
OP
3 steps:
open, stop, close, open...
Step-step command operates in
4 steps:
open, stop, close, stop, open...
EN
(OFF)
OFF
1
2
3
(OFF)
OFF
1
2
(2)
1
10
(OFF)
OFF
3
4
5
(OFF)
OFF
1
2
(4)
2
3
4
21