Vimar ELVOX SW24.W Guía Rápida Para El Instalador página 18

Tarjeta de mando con pantalla y receptor de radio 433 mhz incorporado
Ocultar thumbs Ver también para ELVOX SW24.W:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
SW24.W
All sub-menus are described in the following table:
Motor parameters
Sub
Description
menu
Type of actuator used
Warning! If set to OFF the
board performs no com-
mand !
O1
Not set
Ekko 300/400D (EAM2/EAM3)
Hiddy 200D (EIM1)
Hiddy 350D (EIM2.24)
Type of position control
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
O2
Virtual encoder: the control
panel calculates the gate position
using the electric motor operating
parameters
Encoder EAM2, EAM3, EIM1
Type of limit switch on opening
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
No limit switch on opening: the
electric motor stops at the end of
O3
the working time
Stop limit switch on opening:
the limit switch stops the motor
Limit switch in proximity open-
ing: the limit switch allows the
manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
Type of limit switch on closing
Automatically set with the choice
of actuator.
You are advised not to change
the setting given by the type of
actuator.
No limit switch on closing: the
electric motor stops at the end of
O4
the working time
Stop limit switch on closing: the
limit switch stops the motor
Limit switch in proximity clos-
ing: the limit switch allows the
manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
Note:
O2, O3, O4 are automatically set with the choice of actua-
tor. You are advised not to change the setting given by the
type of actuator.
16
Motor travel calibration procedure
Rapid travel calibration.
The calibration is done fully automatically
Values
and sets:
(default)
- The slowdown in opening at 20% of the
- The slowdown in closing at 20% of the total
(OFF)
- Offset in opening at 3 s and in closing at 6 s
- Pedestrian position at 30% leaf 1
OFF
Button Msg on
1
2
3
-
PP
(3)
-
LRNE
-
2
3
-
(OFF)
-
-
OFF
-
1
-
-
2
-
-
Advanced travel calibration.
The calibration allows the installer to choose:
(OFF)
- Slowdown position in opening and closing
- Offset for opening and closing
- Pedestrian opening position leaf 1
Button Msg on
OFF
-
1
PP
LRNA
2
-
PP
PP
EN
total travel
travel
Phase description
display
PP
Wait for start of calibration
procedure
CL 2
When button pressed: motor
2 closing and search for
closing stop
CL 1
Motor 1 closing and search
for closing stop
OP 1
Motor 1 opening travel
measurement and search
for stop
OP 2
Motor 2 opening travel
measurement and search
for stop
CL 2
Motor 2 closing travel meas-
urement
CL 1
Motor 1 closing travel meas-
urement
OPC1
Motor 1 opening current
curve reading
OPC2
Motor 2 opening current
curve reading
CLC2
Motor 2 closing current
curve reading
CLC1
Motor 1 closing current
curve reading
END
End of procedure
Phase description
display
PP
Wait for start of calibration
procedure
CL 2
When button pressed:
motor 2 starts closing and
searches for closing stop
CL 1
Motor 1 starts closing and
searches for closing stop
OP 1
Start opening motor 1 When
button pressed: slowdown
start position on opening
setting
OP 1
When button pressed end
of travel position setting or
continuation to the stop
Tabla de contenido
loading