Vimar ELVOX SW24.W Guía Rápida Para El Instalador página 21

Tarjeta de mando con pantalla y receptor de radio 433 mhz incorporado
Ocultar thumbs Ver también para ELVOX SW24.W:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
SW24.W
Acceleration time when closing
motor 2
Maximum acceleration (0 s to
T39
reach normal speed)
Minimum acceleration (2.0 s to
reach normal speed)
Note:
T36, T37, T38, T39 are the times during which the
motor accelerates to reach the normal opening
speed (adjustable at intervals of 0.1 s)
Deceleration ramp motor 1
Steep ramp (maximum decelera-
T40
tion)
Low ramp (minimum deceleration)
Deceleration ramp motor 2
Steep ramp (maximum decelera-
T41
tion)
Low ramp (minimum deceleration)
Note:
T40 and T41 are the deceleration ramp between
normal motor speed and slowdown speed.
Auxiliary output configuration
Sub
Description
menu
Electric lock
Output off
Electrical solenoid lock
Electrical drop lock
19
Electrical magnetic lock (suction)
on in closing
Electrical magnetic lock (suction)
on in opening and closing
Electrical solenoid lock excita-
tion time
(adjustable at intervals of 0.1 s)
19T
0.5 s (minimum time)
5.0 s (maximum time)
Terminal A1 output type
Output off
Gate open warning light (SCA)
Operation as per SCA parameter
setting
Auxiliary Radio output (RAU)
Operation as per RAU parameter
setting
Courtesy light (LCO)
On during leaf movement and for
the amount of time after the leaf
A1
stopping set in parameter LCO
Zone light (LZO)
On during leaf movement
Gate left open (OAB)
On if the gate remains open for a
time longer than that defined by
the open gate alarm logic (L16)
Maintenance (MAN)
Output off when the number of
maintenance signalling manoeu-
vres (MNPS) is reached in the
diagnostics section
Terminal A2 output type
(0.5)
Output off
Gate open warning light (SCA)
0
Operation as per SCA parameter
setting
2.0
Auxiliary Radio output (RAU)
Operation as per RAU parameter
setting
Courtesy light (LCO)
On during leaf movement and for
the amount of time after the leaf
(30)
stopping set in parameter LCO
0
Zone light (LZO)
On during leaf movement
100
Gate left open (OAB)
(30)
On if the gate remains open for a
time longer than that defined by
0
the open gate alarm logic (L16)
Maintenance (MAN)
100
Output off when the number of
maintenance signalling manoeu-
A2
vres (MNPS) is reached in the
diagnostics section
Synchronization output, com-
Values
pass type interlock (INB)
(default)
(1)
Automatically configures input S4
OFF
as synchronization input without
1
any choice by the user.
2
The control panel consents to the
gate opening only if the other gate
3
is in the closed position.
Synchronization output, com-
4
pass type interlock (INP) with
presence signal.
(1.2)
Automatically configures input S4
as synchronization input and S3 as
0.5
presence input without any choice
5.0
by the user. The control panel
(1)
consents to the gate opening only
OFF
if the other gate is in the closed
position and the presence input is
1
occupied.
Auxiliary Radio Output Configu-
ration
2
Impulsive: the output is active for
1 s following the RAU command
from the remote control
Timed: the output is active for the
RAU
3
time set in the RAUT parameter
following the RAU command from
the remote control
4
Bistable: the output works in Step-
Step ON/OFF mode
RAU output timing
5
1 s (minimum time)
RAUT
600 s (maximum time)
Courtesy light timer
1 s (minimum time)
LCO
6
300 s (maximum time)
EN
(2)
OFF
1
2
3
4
5
6
7
8
(1)
1
2
3
(1)
1
600
(120)
1
300
19