4. HOW TO RESET DEFAULT BUTTON PANEL SETTINGS

The button panel must be reset to return the parameters to the default factory settings.
Proceed as follows:
A. Hold the program button (10) pressed for 1 second. The operations to be performed are those described in
steps B4-B12.
B. Simultaneously hold button 1
2
for button panel Ref. 1784/4 for 3 seconds.
B.1. The display shows the screen where you need to enter the password.
Ref. 1784/3
B.2. Proceed as follows to enter the password (default 1937):
1. Press button 1 repeatedly until the first digit of the password appears on the display in the box
associated with the button.
Ref. 1784/3
2. Press button 2 repeatedly until the second digit of the password appears on the display in the box
associated with the button.
Ref. 1784/3
DS1784-003
and button 2
for button panel Ref. 1784/3 or button 1
Button 1
Button 2
Button 3
Button 4
Button 1
Button 2
Ref. 1784/4
Ref. 1784/4
Ref. 1784/4
and button
Button 1
Button 2
Button 3
Button 4
Button 1
Button 2
27