DATE AND TIME
The Touch module has an internal clock which maintains the date and time settings for 5 days even if the
power supply is cut off
•
Sync mode
◊
Autonomous: the date and time are adjusted Locally (via the internal clock) or via the Cloud service
("Sync type" menu)
◊
Master: the Touch module set as Master will synch the date and time on the devices set as Slave with
its own. The date and time are adjusted Locally (via the internal clock), via NTP server or via the Cloud
service ("Sync type" menu)
◊
Slave: the date and will be synced by the device set as Master
•
Address: if the Touch module is set with Master "Sync mode" and NTP "Sync type", enter the address of
the NTP server. If the Touch module is set with Slave "Sync mode", enter the address of the device set as
Master
•
Time difference: select the time difference
•
Show date/time: if the option is enabled, the Touch module screen will show the date and time (disabled
by default)
•
System date: set the current date and time. Click the button to the right of the field to sync the date and
time on the Touch module with the date and time on the computer you are using
•
Time format: select the time display format (12H or 24H, default: 24H)
•
Date format: select the date display format (YYYY/MM/DD, DD/MM/YYYY, MM/DD/YYYY, default: DD/
MM/YYYY)
•
Date separator: select the date separator (/, ., -, default: /)
HARDWARE
•
Configure RFID: this option is used to enable the RFID reader supplied (disabled by default)
◊
Disabled: the RFID reader is disabled
◊
Enabled: the RFID reader is enabled
◊
Enabled with RS485 connection: the RFID reader connected to the control panel art. SK9020 with
RS485 serial port is enabled
•
Maximum backlight brightness day: set the brightness value for the touch screen during the day when it
is in use (from 10 to 100, default: 100)
•
Minimum backlight brightness day: set the brightness value for the touch screen during the day when it
is in standby (from 10 to 100, default: 70)
•
Maximum backlight brightness night: set the brightness value for the touch screen at night when it is in
use (from 10 to 100, default: 30)
•
Minimum backlight brightness night: set the brightness value for the touch screen at night when it is in
standby (from 10 to 100, default: 10)
WELCOME MESSAGES
•
Message header: free area for entering the welcome message header
•
Welcome message: free area for entering the welcome message