In the following pages you can find a functions
diagram with information concerning.
For the use of the function chart proceed as
follow:
•
Press DOWN key to flow the chart from the
top to the bottom. The functions dEF, t.AP1,
t.AP2 etc. will be appear.
•
Press UP key to flow the chart from the bottom
to the top.
•
Press MENU key to flow the chart horizontally;
for example, if the t.ChP function is displayed,
by pressing the MENU key the number 7.0 will
be dispayed.
Increase the number pressing UP or DOWN.
Press MENU to display function t.ChP again.
Model
Power supply
Max motors load
Max accessories load 24V
Working temperature
Protection fuse
Dimensions
Weight
Protection
TECHNICAL SPECIFICATIONS
PD5
PD5-120V
230VAC - 50Hz
120VAC - 60Hz
700W
10W
-20 ÷ +60 °C
-20 ÷ +60 °C
F1 = 5A
295 x 230 x 100 mm
1600 g
IP55
27
WARNING LIGHT DESCRIPTION
The warning light shows in real time the state of
the gate:
STOP
light off
IN PAUSE
light always on
OPENING
the light flashes slowly (2 Hz)
CLOSING
the light flashes rapidly (4 Hz)
PD7
230VAC - 50Hz
700W
700W
10W
10W
-20 ÷ +60 °C
F1 = 8A
F1 = 5A
PD7-120V
120VAC - 60Hz
700W
10W
-20 ÷ +60 °C
F1 = 8A
195 x 145 x 80 mm
1200 g
IP55