5.8.1 - Synoptic
The synoptic shows the system diagram and operating status in real time.
In detail, the synoptic shows:
• The current mode of operation
• The modes of operation menu icon
• The desired temperatures setting icon
• The hydraulic circuit and the refrigerating circuit (blue colour indicates cooling in progress, red colour
indicates heating in progress)
• Water/refrigerant plate exchanger (black colour if it is switched off)
• Electric heaters collector (black colour if the electric heaters are switched off, red colour if they are on)
• Main circuit pump (black colour if the pump is switched off, green colour if it is on)
• Three-way valve
• Photovoltaic contacts input (sun on when contacts are enabled)
• Solar thermal circuit coils
• The fan coil unit (can be switched with the radiant panel symbol by simply touching the fan coil unit icon)
5.8.2 - Climatic curves
To optimize energy saving, two climatic curves are available, one for heating and one for cooling.
These curves allow to adjust water temperature to external air temperature and, therefore, thermal load.
EN - 34