5.2 - HOLIDAY MODE
Press the icon (P13/P17) to display the setting screen of holiday periods.
It is possible to set up to 3 holiday periods in one year.
In this system, the pump anti-blockage and antifreeze protections will remain active (the anti-Legionella
function is disabled).
5.3 - NIGHT MODE
Press the icon (P5) to display the screen of the night function activation range.
In this screen it is possible to set the activation range of the function.
5.4 - MODES OF OPERATION
Press the icon (i1) to access the menu "mode selection".
Press to start cooling.
The heat pump produces cold water until the set
temperature is reached (fixed value or dynamic value
if the climatic curve is enabled).
Press to start heating.
The heat pump produces hot water until the set temperature is reached (fixed value or dynamic
value if the climatic curve is enabled).
Press to start the production of domestic water only.
Press to set the desired temperatures in energy saving mode (ECO values).
The energy saving mode has no effect if the climatic curves are enabled.
Press to enable the night function (limits the power and noise level of the external unit).
Press to enable the production of domestic hot water under any condition of the external temper-
ature using all power available.
Press to disable the production of domestic water
Press to confirm any change to the mode of operation
Press to return to the main menu
EN - 31
TOWER SMALL