Option Description - DART Controls 250G CONTROL Serie Manual De Instrucciones

Ocultar thumbs Ver también para 250G CONTROL Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TACHOMETER FEEDBACK
Improves speed regulation to ±1/2% of base speed. Contol
goes to full output when input goes to zero, above and
beyond MAX trimpot setting
+
6 VDC at BASE SPEED (3 VDC at
TACHOMETER
1000 RPM for 1800 RPM MOTOR)
-
INHIBIT (USED INDEPENDENTLY)
The customer supplied SPST switch is connected
in series between the speedpot HI (P1-3) and the
Inhibit pin (P2). To inhibit, speedpot HI is closed to
the Inhibit pin. To restart, the switch is returned to
open. NOTE: The control will stop and start fast,
accel is bypassed.
LO
WIPER
SPEEDPOT
HI
NOTE: Permits starting and stopping of motor without breaking AC lines. In the event of SCR failure or false
triggering, the Inhibit circuit will not stop motor.
Always use a shielded wire when connecting to the inhibit terminal. The shield should be connected
to -Armature or Common of the control.
-5 option
Isolated 4-20 ma.Signal Follower
4 to 20mA ........... -5
Input impedance: 500 ohms or less
DO NOT USE TRIMPOT CHART TO
ADJUST MIN AND MAX TRIMPOTS
ON MAIN BOARD. IF ADJUSTMENT
IS NEEDED THEN REFER TO THE
SETUP PROCEDURE BELOW.
This option replaces the speedpot with a 4-20 ma. signal to control speed. The current signal input can be either grounded or
ungrounded. The board sets on spacers screwed to terminals P1-1, P1-2, and P1-3 on the main board using long screws. The
current source connects to the + and - two position terminal strip (P16-1 and -2) on the -5 option board.
The Linearity trimpot on the -5 option board is set at the factory for proper linearity, however this trimpot may need to
be re-set after tuning the controls Max and Min trimpot settings for your specific application. If needed then refer to the setup
procedure below.
P2 INHIBIT
P1-4 -ARM
NOTE: NEED 1% OR LESS - TACH OUTPUT RIPPLE
INHIBIT
P1
(P2)
-1
-2
SPST
-3

OPTION DESCRIPTION

LINEARITY ADJUSTMENT
CURRENT
SOURCE
P16
TACHOMETER FOLLOWER
Allows control output to follow tachometer voltage.
+
TACHOMETER
12 VDC at FULL SPEED
-
INHIBIT (USED WITH SPEEDPOT)
The Common of the SPDT switch is connected to
control pot HI and is switched between Speedpot
Hi and the Inhibit pin (P2). To inhibit (stop motor),
speedpot HI is closed to the Inhibit pin. To restart,
the switch is returned to Speedpot Hi. NOTE: The
control will stop fast and soft start through a fixed
acceleration range.
SPEEDPOT
P1
LO
-1
WIPER
-2
HI
-3
Field or Factory Installed
Available on Chassis Only*
follow a 4mA to 20mA
-1 -2
250/500
-
-
-
-4
-5
(250G TERMINAL STRIP)
8
P1-2 POT WIPER
P1-1 POT LO
INHIBIT
(P2)
SPDT
Permits the control to
grounded or
ungrounded current
-6
-7
-8
-9 -10
-11
P1
Tabla de contenido
loading

Este manual también es adecuado para:

251g-12c253g-200c251g-12e253g-200e

Tabla de contenido