Connecting Electric Dryers; Four=Wire Power Cord; Three=Wire Power Cord - KENMORE ELITE 796.6141 Serie Manual De Uso Y Cuidado

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ELECTRIC DRYERS (continued)
CONNECTING
ELECTRIC DRYERS
,& WARNING:
Connect the power cord to the fermlnal
block. Each
colored wire should be connected to the termlnal
block
screw with the same color wire around it. For example,
connect the black power cord wire to the termlnal
block
screw with the black wire around it. Failure to follow
these instructions may result in a short or overload.
Four=Wire Power Cord
* A 4=wire connection is required
for all
mobile and manufactured home installations,
as well as all new construction after
January 1, 1996.
* A UL-listed strain relief is required.
* Use a 30=amp, 240=volt,
4=wlre, UL=llsted power cord
with #10 AWG=mlnlmum
copper conductor and closed
loop or forked terminals with upturned ends.
0
Remove the terminal
block access cover on the upper
back of the dryer.
Install a UL-tisted strain relief into the power cord
through-hole.
Thread a 30-amp,
240-volt,
4-wire, UL-listed power
cord with #10 AWG-minimum
copper conductor
through the strain relief.
Hot
_
Neutral
(Black)
Ground
Wire
Transfer the dryer's ground wire from behind the green
ground screw to the center screw of the terminal block.
Attach the two hot leads of the power cord to the outer
terminal block screws.
Attach the white neutral wire to the center screw of
the terminal block.
Attach the power cord ground wire to the green
ground screw.
TIGHTEN ALL SCREWS SECURELY.
_t
Reinstall the terminal block access cover.
Grounding through the neutral conductor is prohibited
for: (1) new branch=circult installatlons, (2) moblle
homes, (3) recreational vehicles, and (4) areas where
local codes prohibit grounding
through
the
neutral conductor.
Three=Wire Power Cord
* A 3=wlre connection is NOT permitted on
new construction after January 1, 1996.
" A UL-listed
strain relief is required.
* Use a 30-amp,
240-volt,
3-wire, UL-tisted power cord
with #10 AWG-minimum
copper
conductor
and closed
loop or forked terminals
with upturned
ends.
Remove the terminal block access cover on the upper
back of the dryer.
Install a UL-listed strain relief into the power cord
through-hole.
Thread a 30-amp,
240-volt,
3-wire, UL-listed power
cord with #10 AWG-minimum
copper conductor
through the strain relief.
/'-_
Hot
(Black)
Ground
Screw
////11
White wire from
dryer harness
Neutral
O
O
O
@
O
Attach the two hot leads (black and red) of the
power cord to the outer terminal
block screws.
Attach the neutral (white) wire to the center terminal
block screw.
Connect the external ground (if required by local
codes) to the green ground screw.
TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal
block access cover.
13
Tabla de contenido
loading

Este manual también es adecuado para:

796.7141 serie

Tabla de contenido