Operation with emergency hand crank
During maintenance works or in the case of an electrical fault, the door can be moved towards the OPEN
or CLOSED positions with the help of the emergency operation equipment.
WARNING:
- Emergency operation must only be carried out from a safe standing position
- Emergency operation must only be carried out when the motor is stationary.
- The system must be disconnected from the power supply during emergency operation
- Push the emergency hand crank into the drive as far as it will go. The control voltage is interrupted and
the door can no longer be electrically operated.
- Move the door in the OPEN or CLOSE direction by turning the emergency hand crank.
- Remove the emergency hand crank from the drive after completing emergency manual operation. The
control voltage will be interrupted and the door can no longer be operated electrically.
04030562EN 09 2021-03
Roll Up Door with membrane keypad
USE AND MAINTENANCE
39