6.2 ORDINARY MAINTENANCE
IMPORTANT: Daily at the beginning of each work shift to check the correct operation of the door and
its emergencies, in case of any anomaly it is necessary to promptly contact the person responsible
Check the operation
of the safety devices
Checking the state
of the gear reducer
gaskets
Checks on the motor
and bearings
Engine Brake Checks
Check shaft and
relevant support
Coated fabric cover
Photocells
Electrical controls
and wiring
Movement and
operation of the door
Number of cycles
(opening and closing)
Only use original spare parts Incold
04030562EN 09 2021-03
Roll Up Door with membrane keypad
PERIODIC INSPECTIONS / MAINTENANCE:
Check that the safety devices in the doors are
working properly: sensitive edge at the bottom of
the fabric ; Photocell system; Photocell barrier
system (if fitted) and operation of the stop
button located on the main panel.
Visual inspection of any oil leakage.
Check if the engine moves freely. If necessary,
lubricate the bearings.
Removing the plastic frame from the brake
engine and checking the brake disc. If worn to
replace.
Visual inspection of the shaft and checking of
correct tightening of the nuts and bolts.
Checking for tears, wear, etc. .
Checking the proper operation, during the door
closing
Checking the conditions of electrical wires and
connections.
Checking the proper operation of the door:
Opening, closing, and partial opening
Periodically check the number of maneuvers to
schedule proper maintenance .
IMPORTANT: The maximum number of door
maneuvers is 45 open-close cycles per hour
USE AND MAINTENANCE
Daily at the beginning
of each work shift
Semester / no later
than every 50,000
opening
Semester / no later
than every 50,000
opening
Semester / no later
than every 100,000
opening
Semester / no later
than every 50,000
opening
Semester / no later
than every 50,000
Daily at the beginning
of each work shift
Semester / no later
than every 50,000
opening
Daily at the beginning
of each work shift
45