3.4.3 Control keypad

Display
Keys + AND -
-Partial
opening key
-Enter Key in
the settings
menu

3.4.4 Alarms management

Connect:
During the normal operating and calibration phases of the door travel, a check is performed on any
alarms that may occur and an alarm appears if an error is detected.
If an alarm is present, it can be reset by holding the key – and entering the password 3333. There are 3
attempts to correctly enter the alarm reset password and a 60" timeout for keypad inactivity.
If the same alarm occurs again, contact the Incold technical assistance office.
• Alarm 01: inverter overcharge.
• Alarm 02: inverter short-circuit.
• Alarm 03: too high continuous inverter voltage.
• Alarm 04: too low continuous inverter voltage.
• Alarm 05: motor overcharge.
• Alarm 06: motor thermal issue.
• Alarm 07: encode chain ("crank stop" is displayed).
• Alarm 08: inverter driver temperature.
• Alarm 09: PFC not started.
• Alarm 11: failed photocell 1 test.
• Alarm 12: failed photocell 2 test.
• Alarm 17: communication with the inverter.
• Alarm 18: roll-up opening/closing timeout.
• Alarm 19: roll-up calibration data error (loss of data saved in the memory).
• Alarm 20: roll-up position data error (roll-up position not coherent with the calibration data).