stallation Manual of Room Air Conditioner
Operation
(5) Air flow direction adjustment
After operation mode is selected, vertical flap will open automatically according to the mode.
Referring to the Fig.
Necessary Tools for Installation
iver
acksaw
ole core drill
Up and down (Use remote controller)
panner(17,19 and 26mm)
Press SWING button, vertical flap will move within
the range shown in the Fig. Press SWING button
stop it at a fixed position.
ssory parts
Number
ssory parts
of
articles
1
mote controller
2
R-03 dry battery
Mark
1
A
Cautions:
Mounting plate
It is advisable not to keep vertical flap at
B
1
C
downward position for a long time in COOL
Drain hose
D
or DRY mode, otherwise, condensate
4
5
E
Plastic cap
water might occur.
F
1
Drain-elbow
G
(6) Unit stop
Press ON/OFF button.
4
Cushion
Only time remains on LCD.
1
Vertical flap closes automatically.
e supporting plate
1
Connecting cable
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more
helpful for a better air circulation.
As warm air flows upward in HEAT mode, adjusting air flow downward will be much more
helpful for a better air circulation.
Be careful not to catch a cold when cold air blows downward.
It is harmful to your health in summer to go frequently in and out of places where temp.
difference is above 7
More than this, unit's load can be reduced and power consumption cut down as well. So, you'd
better set a temp. difference of 3-5
The marks from
The distance between the indoor unit and the floor should be
more than 2m.
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
COOL
5.Torque wrench(17mm,22mm,26mm)
o
About 10
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
o
About 10
o
COOL
About 45
Optional parts for piping
o
HEAT
About 60
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
Left
right
Right
Below
o
C. Temp. difference of 3-5
to
in the figure are the parts numbers.
A
G
9.Nipper
10.Gas leakage detector or
Left and right air flow adjustment
11.Measuring tape
(manual)
Move the horizontal blade by a knob on air
conditioner to adjust left and right direction
The models adopt HFC free refrigerant R410A
referring to Fig.
Cautions:
When humidity is high, condensate water
might occur at air outlet if all horizontal
louvers are adjusted to left or right.
Cautions:
Unit won't restart until 3 minutes have
elapsed, due to system protection.
HEAT mode is not available on
cooling only unit.
o
C will remove your fatigue.
o
C between indoor and outdoor temp. in COOL mode.
8
HEAT
o
About 60
soap-and-water solution
Attention must be paid to
the rising up of drain hose
12.Reamer