Operation
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
COOL,HEAT and DRY operation
Recommendations:
HSU-09H03/R2(DB)
HSU-12H03/R2(DB)
HSU-12HB03/R2(DB)
(1) Unit start
HSU-18H03/R2(DB)
HSU-12HD03/R2(DB)
Press ON/OFF button, unit starts.
Previous operation status appears on display. (Not Timer setting)
Power indicator on indoor unit lights up.
Fixing of outdoor unit
(2) Select operation mode
Press MODE button. For each press, operation
mode changes as follows:
AUTO
COOL
Indoor Unit
Unit will run in operation mode displayed on LCD.
Stop display at your desired mode.
Place, robust not causing vibration, where the body can be supported
sufficiently.
(3) Select temp. setting
Place, not affected by heat or steam generated in the vicinity, where
Press TEMR button.
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
Every time the button is pressed, temp. setting increases 1
outdoor unit.
Every time the button is pressed, temp. setting decreases 1
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
Unit will start running to reach the temp. setting on LCD.
to drawings).
Place where the distance of more than lm from televisions, radios,
(4) Fan speed selection
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
Press FAN button. For each press, fan speed changes
indoor unit can receive signals when the fluorescent lamps in the room
as follows:
are lightened.
AUTO
LO
Unit runs at the speed displayed on LCD.
In DRY mode, when room temp. becomes 2
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name p
temp. setting, unit will run intermittently at LO speed
Install an exclusive branch circuit of the power.
regardless of FAN setting.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
Hints
On cooling only unit, heating mode is not available.
Remote controller can memorize each operation status. When starting it next time,
just press ON/OFF button and unit will run in previous status.
To this unit, both liquid and gas pipes shall be insulated
as they become low temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
The thickness of the pipe must be 0.8mm at least.
Use COOL in summer.
Use DRY in spring, autumn and in damp climate.
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizonta
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with na
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
DRY
HEAT
FAN
Selection of Installation Place
MED
HI
Power Source
o
C higher than
Selection of pipe
113.5
583
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Use HEAT in winter
HSU-22H03/R2(DB)
Place, which is less affected by rain or direct sunlight and
sufficiently ventilated.
Place, possible to bear the unit, where vibration and nois
not increased.
o
Place, where discharged wind and noise do not cause a
C
nuisance to the neighbors.
o
C
Place, where a distance marked
in the above figure.
COOL operation starts when room
temp. is higher than temp. setting.
Temp. setting+2
Temp. setting
7
Liquid pipe
Gas pipe
113.5
ON/OFF
TEMP
3
1
3
6
Outdoor Unit
MODE
SET
2
FAN
TIMER
4
SWING
CLOCK
is available as illustr
5
SLEEP
LOCK
RESET
Ultra-low air flow
o
C
On reaching temp. setting, unit
will run in mild DRY mode.
HSU-12H03/R2(DB)
HSU-09H03/R2(DB)
HSU-12HB03/R2(DB)
HSU-18H03/R2(DB)
HSU-12HD03/R2(DB)
HSU-22H03/R2(DB)
6.35mm(1/4")
6.35mm(1/4")
9.52mm(3/8")
12.7mm(1/2")