Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Hammer
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HC FC free refrigerant R410A
more than 10cm
(3 7/8)
more than 10cm
(3 7/8)
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
The marks from
to
A
in the gure are the
G
parts numbers.
The distance between
the indoor unit and the
oor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain suf ciently the operating means to the user according to this manual.
NO.0010536243
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
corresponding name plate.
more than 15cm
more than 20cm
(7 7/8)
(23 5/8)
Selection of Installation Place
Indoor Unit - Select a plocation that is
Robust not causing vibration, where the body can be supported sufficiently.
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
Nearby a power receptacle. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent
Outdoor Unit - Select a plocation that is
Not less affected by rain or direct sunlight and is sufficiently ventilated.
Strong enough to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
Attention must be paid to
the pitch of drain hose
more than 10cm
(3 7/8)
A
C
(5 7/8)
more than 25cm
(9 7/8)
lamps in the room are in use.
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor xing dimensions of the
outdoor unit (Unit:mm / inch)
For:HSU18VCK-W
113.5
633
113.5
(4 1/2)
(24 7/8)
(4 1/2)
For:
HSU24VCK-W
184
184
580
(7 1/4)
(7 1/4)
(22 7/8)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts rmly
and horizontally.
When tting the unit to wall
surface, roof or rooftop, x
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, x the unit by attaching a
vibration-proof mat.
Tabla de contenido
loading

Resumen de contenidos para Haier HSU18VCK-W

  • Página 5: Preparación

    Cubierta de orificio de entubación Dimensiones de fijación al suelo de la más de10 cm Organización de la dirección de unidad exterior (Unidad :mm / pulgada) (3 7/8) los tubos Para:HSU18VCK-W Izquierda trasera Izquierda Derecha trasera 113.5 113.5 (4 1/2)
  • Página 6: Unidad Interior

    1. Pase la manguera aislante a través del hueco de los materiales de aislamiento de Accesorios calor de la unidad interior. 2. Inserte los cables eléctricos de interior / exterior a través de la parte trasera de la unidad interior y tire de ellos desde la parte delantera. A continuación, conéctelos. 3.
  • Página 7: Conexión

    Unidad interior ● En caso de que la longitud del tubo B sea superior a 10m, deberá cargarse el refrigerante a razón de 50 g/m. HSU18VCK-W Cable de alimentación: 2 hilos con toma de tierra 14AWG HSU24VCK-W Cable de alimentación: 2 hilos con toma de tierra 14AWG Conexión...
  • Página 8: Etiqueta De Carga De Refrigerante

    5. ¿No existen fugas de gas? 1. Cortar el tubo 2. Eliminar las rebabas Cuchilla de conicidad En caso de que exista una fuga de gas, apriete las conexiones de los tubos. Si la fuga se detiene, proceda al paso 6. 3.
  • Página 12: Etiquette De Charge De Réfrigérant

    5. Pas de fuite de gaz? Correct Incorrect En cas de fuite de gaz, resserrez les pièces de connexion du tuyau. Lorsque la fuite est maîtrisée, passez à l'étape 6 Insuffisant Evasement endommagé Fissure Partiel Vers extérieur Vidange 6. Détachez le tuyau de charge de l'orifice d'entretien, ouvrez la vanne à 2 et 3 voies. Tournez le robinet de la vanne dans le sens antihoraire.

Este manual también es adecuado para:

Hsu24vck-w

Tabla de contenido