Operation
Base Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select temp.setting
button
Press
Every time the button is pressed, temp.setting
o
increase 1
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
o
decrease 1
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
3.Fan function
Press FAN button.
For each press
button fan speed
changes as
follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
Remote
Operation
Mode
Controller
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according to
AUTO
room temperature. When FAN is set to AUTO the air
conditioner automatically adjusts the fan speed according
to room temperature.
COOL
In DRY mod
●
DRY
than temp.setting+2
speed regardless of FAN setting.
In HEAT mode, warm air will blow out after a short
period of the time due to cold - draft prevention function.
HEAT
When FAN is set to AUTO, the air conditioner automatically
adjusts the fan speed according to room temperature.
In FAN ope
HEAT mode but only in FAN mode, AUTO is not available in
FAN
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
TURBO
SLEEP
TIME
TIME
ON
OFF
Display
circulated
HI
AUTO
●
●
Note
e , when room temperature becomes lower
o
C, unit will run intermittently at LOW
ration mode , the unit will not operate in COOL or
●
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
Room
Timer
Designated
temperature
mode
temperature
o
o
Above 23
C
26
C
No
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
o
temperature is below 16
C, do not use it in the
normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice, release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Air Flow Direction Adjustment
●
1.Status display of air flow
Vertical flap
Pos.1
Initial state
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
2.Left and right air flow adjustment
For each press of
displays as follows :
remote controller:
Pos.1
Pos.3
Pos.2
Pos.5
Pos.6
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or at air outlet if all vertical louvers are right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller
controller will automatically memorize the previous set swing position.
Pi
Fan
Operation
speed
mode
AUTO
COOL
Pi Pi
(Auto swing)
button, remote controller
Pos.4
mode ,
2