Phcbi MCO-170M Instrucciones De Operación página 72

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ALARMS, SAFETY, AND SELF-DIAGNOSIS
Tables 7–9 show the behaviour of the alarm (buzzer) and ring back function when pressing the Buzzer
key.
Table 7. In cases other than those covered in Tables 8 and 9
Remote Alarm setting
ON: Remote alarm setting not connected with
Buzzer key (remote alarm is cancelled)
OFF: Remote alarm setting connected with
Buzzer key (remote alarm is not cancelled)
Note: Resolve the cause of the alarm, as the alarm itself is not deactivated by pressing the Buzzer key.
Table 8. In cases of high-limit temperature alarm or Err38
Remote Alarm setting
ON: Remote alarm setting not connected with
Buzzer key (remote alarm is cancelled)
OFF: Remote alarm setting connected with
Buzzer key (remote alarm is not cancelled)
Note: Close the outer door when Err38 is activated.
Table 9. In cases of Err01, Err02, Err11, Err12, Err18, or door alarm*
Remote Alarm setting
ON: Remote alarm setting not connected with
Buzzer key (remote alarm is cancelled)
OFF: Remote alarm setting connected with
Buzzer key (remote alarm is not cancelled)
*2: The remote alarm does not work for the door alarm.
Notes:
• When Err01 is activated, connect the new CO
In addition, when the optional MCO-21GC is installed and the gas supply is switched to the reserve gas
cylinder, press the Buzzer key and replace the gas cylinder.
• When Err02 is activated, press the Buzzer key and replace the N
72
Buzzer from O
Ring Back
When pressing
setting
the Buzzer key
ON
OFF
OFF
(Alarm is not
ON
cancelled)
OFF
Buzzer from O
Ring Back
When pressing
setting
the Buzzer key
ON
OFF
ON
ON
OFF
Buzzer from O
Ring Back
When pressing
setting
the Buzzer key
ON
OFF
OFF
(Alarm is
ON
cancelled)
OFF
gas cylinder and press the Buzzer key to stop the buzzer.
2
/CO
incubator
2
2
When the Ring Back
When pressing
set time passes
the Buzzer key
ON
ON
OFF
ON
OFF (Alarm is
OFF
not cancelled)
/CO
incubator
2
2
When the Ring Back
When pressing
set time passes
the Buzzer key
ON
ON
(Under continuation)
(Continue)
2
/CO
incubator
2
2
When the Ring Back
When pressing
set time passes
the Buzzer key
OFF
OFF
(Alarm is already
(Alarm is
cancelled)
cancelled*
gas (O
gas) cylinder.
2
2
Remote Alarm
When the Ring Back
set time passes
ON
(Under continuation)
ON
OFF
Remote Alarm
When the Ring Back
set time passes
ON
(Under continuation)
Remote Alarm
When the Ring Back
set time passes
OFF
(Alarm is already
2
2
)
cancelled*
)
Tabla de contenido

Solución de problemas

loading