Installation

Wiring Connections

IN-LINE/REMOTE BLOWER WIRING
1
Remove the top cover of the electrical box by extract-
ing the two screws. Refer to the illustration.
2
Remove one of the round knockouts using a flat blade
screwdriver.
3
The terminal block is wired for an internal blower.
For in-line and remote blowers, the existing blue and
brown wires must be removed and placed in the two
left positions to accommodate the in-line or remote
blower wire. Refer to the illustration.
Insert Romex
®
wire from the in-line or remote blower
4
through the knockout and secure using an approved
cord stain relief.
5
Connect white to blue, black to brown and green to the
ground screw. Refer to the illustration.
Verify all wires are secure and not pinched between the
6
cover, and install the cover.
MOVE
WIRES HERE
Wiring location
GROUND
TO IN-LINE / REMOTE
BLOWER
In-line/remote blower wiring