Registering Peripherals; Modifying General Parameters; Setting The Date And Time - Honeywell Domonial CMI800 Manual Del Usario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
EKZ008500A

2-2 Registering peripherals

Screen
Action
Select option 1 1 1 1 - - - - REGISTER
Programming main menu
Registering
Perform the action indicated into the peripheral notice to
register it ; generally a tamper opening.
Type OK
View device
Select option 1 1 1 1 - - - - LABEL
Edit device
Label
Delete the original label, and replace it with the
localization of the peripheral, e.g. ENTRANCE, then
validate with OK
Select option 2 2 2 2 - - - - EDIT
Modify device
Select address
Type in the address code, such as 1323 to select a zone for
a detector, then OK
Annex 2 of this document.
Set value
Type in the allocated zone for the detector :
0 for Total, 1 for Part, 2 for Annex or 3 for 24/24, then
validate with OK
Select address
Proceed identically with other parameters for the same
detector, according to the codes reference annex. When
finished, return to main menu with
If the TCU used for programming must be left on the installation, it can be registered by pressing simultaneously the Total arm and Part arm
keys while the panel is waiting for a registering message.
VIEW DEVICE
VIEW DEVICE
VIEW DEVICE
VIEW DEVICE
MODIFY DE
MODIFY
MODIFY
MODIFY
LBL
1-LABEL
Intervenant
TYPE DO
CH D1
2-EDIT
3-DELETE
FAULTS
- T -
EDIT (OK)
EDIT (OK)
EDIT (OK)
EDIT (OK)
2-3 Modifying or deleting registered devices
Screen
Action
Select option 2 2 2 2 - - - - VIEW
Programming main menu
View device
Use the arrows keys to select among the registered or
predefined devices, then validate with OK
Edit device
Proceed with device edition as described in the registering
procedure above.
Alternatively, select option 3 3 3 3 - - - - DELETE
Edit device
Validate with OK
Confirmation

2-4 Modifying general parameters

Screen
Action
Select option 3 3 3 3 - - - - PARAMETERS
Programming main menu
Select address
Proceed as for devices parameters, using the general
parameters section of the address codes annex. For
example, code 331126 will address the entry delay.

2-5 Setting the date and time

Screen
Action
Select option 4 4 4 4 - - - - DATE & TIME
Programming main menu
Key in the required value, then validate with OK
Set date & time
REGISTER
REGISTER
REGISTER
OK to enter device edition mode
OK
OK
LABEL
LABEL
LABEL
OK.
OK
OK
EDIT
EDIT
EDIT
OK. Usual address codes can be found in
OK
OK
OK
OK
OK
DE
DEVICE
DE
VICE
VICE
VICE
LABEL
LABEL
LABEL
LABEL
LABEL
-----------------
CANCEL
CANCEL ( ) VAL
CANCEL
CANCEL
VIEW DEVICES
VIEW
VIEW
DEVICES
DEVICES
DEVICES
DELETE
DELETE
DELETE
OK
OK
OK
PARAMETERS
PARAMETERS
PARAMETERS
DATE & TIME
DATE & TIME
DATE & TIME
Result
The panel waits for a registering message from any
peripheral.
Once the message has been received by the panel,
the TCU will present the View device screen. The
initial device label is its serial number.
> Edit device menu
> Set label screen
> View device screen
> Select address screen
>Set value screen
>Select address screen
> Programming main menu
SELECT ADDRESS
SELECT ADDRESS
SELECT ADDRESS
SELECT ADDRESS
LBL
Intervenant
TYPE F4
ADDRESS
_
1323
VAL(OK)
VAL
VAL
(OK)
(OK)
(OK)
CANCEL
CANCEL
CANCEL
CANCEL( ) VAL(OK)
Result
> View device screen
> Edit device screen
OK.
OK
OK
> Confirmation screen
The device is deleted.
> View device
Result
> Select address screen
Result
> Set date & time screen
OK
OK
OK
> Programming main menu
VALUE
VALUE
VALUE
VALUE
LBL
Intervenant
TYPE F4
1323
DATA:
_
0
VAL(OK)
VAL(OK)
VAL(OK)
NO
NO( )
NO
NO
YES(OK)
YES
YES
YES
E
N
5/64
G
L
I
S
H
(OK)
(OK)
(OK)
Tabla de contenido
loading

Tabla de contenido