Robern M Serie Instrucciones De Instalación página 8

Ocultar thumbs Ver también para M Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Wiring the Electric
DANGER:
To reduce the risk of electrical shock, shut
off power before wiring the cabinet.
CAUTION:
Grounding instructions for permanently
connected products: This product must be
connected to a grounded, metal permanent
wiring system or an equipment-grounding
conductor must be run with the circuit con-
ductors and connected to the equipment-
grounding terminal or lead on the product.
All wiring should be done by a qualified
licensed electrician.
Electricity must be connected to power the M Series
Cold Storage
cabinet.
IMPORTANT:
Power for the Electric should be provided
separately from optional cabinet lights so
that when lights are turned off, the Electric in
the cabinet remains on.
NOTES:
Requires 120 VAC 20 Amp circuit.
Up to 4 cabinets can be wired to the circuit.
1. For surface mounted cabinets, first provide
electric for cabinet through a rough-in hole in
existing wall. The location of the rough-in hole
depends on the cabinet model being installed.
Refer to Figure K to determine where to locate
rough-in hole. Cut rough-in hole, then pull electric
wire through the hole. Be sure to provide 8"
(203.2 mm) of wire to make proper and safe
connections.
2. Before mounting cabinet, remove the four access
screws on the front cover of the electrical box
(see Figure M on page 9 for location). Remove
cover for access to electrical connections.
3. Feed electric wire through wire access hole and
connector in rear of cabinet. Refer to Figure D.
4. Refer to Figure L and make all electrical connections
in accordance with local electrical codes.
209-1095 M Series Cabinet with Cold Storage 9/15/09
WARNING:
An Electrical option cabinet must be wired to a
20 Amp GFI (Ground Fault Interrupter) circuit break-
er when used in bathrooms and all other locations
required by the National Electric Code.
WARNING:
Wire an Electrical option cabinet to a 20 Amp GFI
circuit breaker and circuit breaker panel in accor-
dance with manufacturers' instructions.
3"
(76.2 mm)
19 1/4"
(488.95 mm)
Center Point
1 3/4"
(44.45 mm)
Left Door Model
WIRE ACCESS
HOLE
Cabinet Front
To determine location of Wire Access Hole:
Measure 1 3/4" (44.45 mm) from top, rear of cabinet
Measure 3" (76.2 mm) from left or right, rear edge of cabinet
for Center Point
Circuit Breaker
Panel
20A GFI
Breaker
Cabinet
Electrical
Box Wiring
8
ENGLISH
19 1/4"
(488.95 mm)
Center Point
Right Door Model
WIRE ACCESS
HOLE
Cabinet Front
: Use copper wire only.
NOTE
BLACK
WHITE
GREEN
GROUND
Figure K
3"
(76.2 mm)
1 3/4"
(44.45 mm)
Figure L
Tabla de contenido
loading

Tabla de contenido