2. Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit
Select location
Install the air conditioner in the location
that satisfies the following conditions.
• The place shall easily bear a load
exceeding four times the indoor unit's
weight.
• The place shall be able to inspect the unit
as the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water
drainage.(Suitable dimension "H" is
necessary to get a slope to drain as
figure.)
• The place shall easily connect with the
outdoor unit.
• The place where the unit is not affected
by an electrical noise.
• The place where air circulation in the
room will be good .
• There should not be any heat source or
steam near the unit.
2) Outdoor unit
• If an awning is built over the unit to
prevent direct sunlight or rain exposure,
be careful that heat radiation from the
condenser is not restricted.
• There should not be any animals or
plants which could be affected by hot air
discharged.
• Ensure the spaces indicated by arrows
from the wall, ceiling, fence or other
obstacles.
3) Piping length and the elevation
Pipe Size
(Diameter: Ø)
Capacity
Gas
Liquid
18K BTU
5/8"
1/4"
24K BTU
5/8"
3/8"
36K BTU
5/8"
3/8"
60K BTU
3/4''
1/2''
• If 18K Model is installed at a distance of 15m, 400g of refrigerant should be added (15-5) x 40g = 400g
• Capacity is based on standard length and maximun allowance length is on the basis of reliability.
Length A(m)
Elevation B(m)
Standard
Max.
Standard
5
5
15
5
15
5
5
25
5
5
25
5
Top view
(unit: mm)
Inspection hole
Control box
600
Front view
More than
30cm
F e
n c
o b
e o
s t a
r
c l e
s
Indoor unit
* Additional
refrigerant
(g/m)
Max.
8
40
8
60
8
60
8
70
4
(600X600)
600
Front
H
More than
30cm
More than
70cm
A
B
Outdoor unit