ELECTRICAL WIRING
• All wiring must comply with local
requirements.
• Select a power source that is capable of
supplying the current required by the air
conditioner.
• Use a recognized circuit breaker
25A(18K/24K), 30A(36K), 50A(60K)
between the power source and the unit.
A disconnection device to adequately
disconnect all supply lines must be
fitted.
WIRING CONNECTION
INDOOR UNIT
• Remove the control box cover for
electrical connection between the
indoor and outdoor unit.(Remove two
screws
.)
• Use the cord clamper to fix the cord.
OUTDOOR UNIT
• Remove the control cover for wiring
connection.
• Use the cord clamper to fix the cord.
• Earthing work
Connect the cable of diameter 1.6mm
or more to the earthing terminal provided
in the control box and do earthing.
ÿ
Please check !!
¡ ¡
Perform the electrical wiring work according to
the electrical wiring connection.
Main
power source
Indoor
Control terminal board
Control box
A
1
Control box cover
(On which the Electric
Wiring Connection is put)
2
11
Circuit Breaker
Use a 25A(18K/24K), 30A(36K),
50A(60K) circuit breaker
or time delay fuse.
Switch box
Outdoor
A view
Remote
control cord
1
Cord clamper
Connection
cord between
the indoor unit
and the
outdoor unit
Main terminal board
Control terminal board
Cord
clamper
Cover control
Earth cable